Efficacy of copper and silver ions and reduced levels of free chlorine in inactivation of Legionella pneumophila
- 1 December 1989
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 55 (12) , 3045-3050
- https://doi.org/10.1128/aem.55.12.3045-3050.1989
Abstract
Water disinfection systems utilizing electrolytically generated copper and silver ions (200 and 20, 400 and 40, or 800 and 80 micrograms/liter) and low levels of free chlorine (0.1 to 0.4 mg/liter) were evaluated at room (21 to 23 degrees C) and elevated (39 to 40 degrees C) temperatures in filtered well water (pH 7.3) for their efficacy in inactivating Legionella pneumophila (ATCC 33155). At room temperature, a contact time of at least 24 h was necessary for copper and silver (400 and 40 micrograms/liter) to achieve a 3-log10 reduction in bacterial numbers. As the copper and silver concentration increased to 800 and 80 micrograms/liter, the inactivation rate significantly (P less than or equal to 0.05) increased from K = 2.87 x 10(-3) to K = 7.50 x 10(-3) (log10 reduction per minute). In water systems with and without copper and silver (400 and 40 micrograms/liter), the inactivation rates significantly increased as the free chlorine concentration increased from 0.1 mg/liter (K = 0.397 log10 reduction per min) to 0.4 mg/liter (K = 1.047 log10 reduction per min). Compared to room temperature, no significant differences were observed when 0.2 mg of free chlorine per liter with and without 400 and 40 micrograms of copper and silver per liter was tested at 39 to 40 degrees C. All disinfection systems, regardless of temperature or free chlorine concentration, showed increase inactivation rates when 400 and 40 micrograms of copper and silver per liter was added; however, this trend was significant only at 0.4 mg of free chlorine per liter.This publication has 22 references indexed in Scilit:
- OCCURRENCE AND PARAMETERS OF FREQUENCY OF LEGIONELLA IN WARM WATER-SYSTEMS OF HOSPITALS AND HOTELS IN LOWER SAXONY1988
- Susceptibility of Legionella pneumophila to chlorine in tap waterApplied and Environmental Microbiology, 1983
- Legionnaires' Disease Associated with a Hospital Water System: A Cluster of 24 Nosocomial CasesAnnals of Internal Medicine, 1983
- Legionella pneumophila in cooling water systems: Report of a survey of cooling towers in London and a pilot trial of selected biocidesEpidemiology and Infection, 1982
- Isolation of Legionella pneumophila from water systems: methods and preliminary results.BMJ, 1981
- An Outbreak of Legionnaires' Disease Associated with a Contaminated Air-Conditioning Cooling TowerNew England Journal of Medicine, 1980
- Legionnaires' DiseaseNew England Journal of Medicine, 1977
- ULTRAVIOLET IRRADIATION OF NUCLEIC ACIDS COMPLEXED WITH HEAVY ATOMS—III. INFLUENCE OF Ag + AND Hg 2+ ON THE SENSITIVITY OF PHAGE AND OF TRANSFORMING DNA TO ULTRAVIOLET RADIATIONPhotochemistry and Photobiology, 1973
- Copper(II)—DNA denaturation. II. The model of DNA denaturationBiopolymers, 1972
- Copper(II)–DNA denaturation. I. Concentration dependence of melting temperature and terminal relaxation timeBiopolymers, 1972