Abstract
Existing algorithms of dynamic control of independent pairs of leaves allow optimal DMLC delivery of IMRT to rigid targets translating parallel to leaf trajectories. However, in numerous cases of radiotherapy treatments simplifying assumptions of rigid‐like motions of targets and surrounding tissues are clearly not satisfied. Therefore algorithms have to be developed that allow one to control MLC so that predetermined intensities are delivered to various points in targets that experience compression and expansion at the time of irradiation. Moreover, it is desirable for such algorithms to ensure that delivery of modulated intensity map will be done with minimal expense of monitor units. Derivation of the algorithm that optimizes the DMLC IMRT to mobile, deforming target is presented in this paper. [To illustrate the general algorithm two representative examples of DMLC IMRT delivery to deforming targets are presented in full detail.] Finally, similarities and differences between solutions for immobile targets, for moving, rigid targets and for moving, deforming targets are discussed.Keywords
This publication has 18 references indexed in Scilit:
- DMLC leaf-pair optimal control of IMRT delivery for a moving rigid targetMedical Physics, 2004
- Compensators: An alternative IMRT delivery techniqueJournal of Applied Clinical Medical Physics, 2004
- The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy deliveryMathematical and Computer Modelling, 2003
- Reshapable physical modulator for intensity modulated radiation therapyMedical Physics, 2002
- Detection of lung tumor movement in real-time tumor-tracking radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Compensators for IMRT – An Investigation in Quality Assorance1Zeitschrift für Medizinische Physik, 2001
- Intensity modulation delivery techniques: “Step & shoot” MLC auto‐sequence versus the use of a modulatorMedical Physics, 2000
- Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study.Radiology, 1998
- Respiration gated radiotherapy treatment: a technical studyPhysics in Medicine & Biology, 1996
- Irradiation synchronized with respiration gateInternational Journal of Radiation Oncology*Biology*Physics, 1989