Reshapable physical modulator for intensity modulated radiation therapy
- 12 September 2002
- journal article
- Published by Wiley in Medical Physics
- Vol. 29 (10) , 2222-2229
- https://doi.org/10.1118/1.1508109
Abstract
A new method of generating beam intensity modulation filters for intensity modulated radiation therapy (IMRT) is presented. The modulator was based on a reshapable material, which is not compressible but can be deformed under pressure. A two-dimensional (2D) piston array was used to repeatedly shape the attenuating material. The material is a mixture of tungsten powder and a silicon-based binder. The linear attenuation coefficient of the material was measured to be 0.409 cm(-1) for a 6 MV x-ray beam. The maximum thickness of the physical modulator is 10.2 cm, allowing a transmission of 1.5%. A 16 x 16 square piston array was used to generate a depth pattern in the deformable attenuating material. Each piston has a cross section of 6.37 x 6.37 mm2. The modulator was placed 65 cm from the radiation source of the linear accelerator in the position of the shielding tray. At this position, each piston projects to a 1.0 x 1.0 cm2 area at the isocenter, giving a treatment field of 16 x 16 cm2. The percent depth dose curve and output factor measurement show a slight beam hardening and a 1%-4% increase in scatter fraction when 2.2-4.4 cm uniform thickness filters are in the beam. The surface dose was decreased with the filter in the beam. Ion chamber and verification films were used to verify the entrance dose. The measured absolute and relative doses were compared with the calculated dose. The agreement of measurements and calculations is within 3%. In order to verify the spatial modulation of dose, 1-D dose profiles were obtained using dose calculations. Calculated and measured profiles were compared. The 20%-80% penumbra of the modulator was measured to be 5.5-10 mm. The results show that a physical modulator formed using a 16 x 16 piston array and a deformable attenuation material can provide intensity modulation for IMRT comparable with those provided by currently available commercial MLC techniques.Keywords
This publication has 25 references indexed in Scilit:
- X-ray Beam Equalization: Feasibility and Performance of an Automated Prototype System in a Phantom and SwineRadiology, 2001
- Comparison of algorithms for multileaf collimator field segmentationMedical Physics, 1999
- Multileaf collimator interleaf transmissionMedical Physics, 1999
- Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC techniqueMedical Physics, 1998
- Beam characteristics of a retrofitted double‐focused multileaf collimatorMedical Physics, 1998
- Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segmentsMedical Physics, 1998
- On compensator design for photon beam intensity-modulated conformal therapyMedical Physics, 1998
- Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapyPhysics in Medicine & Biology, 1995
- Peacock™: A system for planning and rotational delivery of intensity‐modulated fieldsInternational Journal of Imaging Systems and Technology, 1995
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994