The UF family of reference hybrid phantoms for computational radiation dosimetry
Top Cited Papers
- 17 December 2009
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (2) , 339-363
- https://doi.org/10.1088/0031-9155/55/2/002
Abstract
Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR (TM). NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros (TM). The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference organ masses from ICRP Publication 89, (3) reference elemental compositions provided in ICRP 89 as well as ICRU Report 46, and (4) reference data on the alimentary tract organs given in ICRP Publications 89 and 100. Various adjustments and refinements to the organ systems of the previously described newborn, 15 year and adult phantoms are also presented. The UF series of hybrid phantoms retain the non-uniform scalability of stylized phantoms while maintaining the anatomical realism of patient-specific voxel phantoms with respect to organ shape, depth and inter-organ distance. While the final versions of these phantoms are in a voxelized format for radiation transport simulation, their primary format is given as NURBS and polygon mesh surfaces, thus permitting one to sculpt non-reference phantoms using the reference phantoms as an anatomic template.Keywords
This publication has 23 references indexed in Scilit:
- Hybrid computational phantoms for medical dose reconstructionRadiation and Environmental Biophysics, 2009
- An image-based skeletal tissue model for the ICRP reference newbornPhysics in Medicine & Biology, 2009
- Realistic CT simulation using the 4D XCAT phantomMedical Physics, 2008
- A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9Physics in Medicine & Biology, 2007
- Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body modelsPhysics in Medicine & Biology, 2007
- Whole-body voxel phantoms of paediatric patients—UF Series BPhysics in Medicine & Biology, 2006
- REVISIONS TO THE ORNL SERIES OF ADULT AND PEDIATRIC COMPUTATIONAL PHANTOMS FOR USE WITH THE MIRD SCHEMAHealth Physics, 2006
- Basic anatomical and physiological data for use in radiological protection: reference valuesAnnals of the ICRP, 2002
- Monte Carlo Calculated Effective Dose to Teenage Girls from Computed Tomography ExaminationsRadiation Protection Dosimetry, 2000
- Skin thickness measurement by pulsed ultrasound: its reproducibility, validation and variabilityBritish Journal of Dermatology, 1982