Imaging of brain tissue pH and metabolites. A new approach for the validation of volume‐selective NMR spectroscopy
- 15 December 1989
- journal article
- review article
- Published by Wiley in NMR in Biomedicine
- Vol. 2 (5-6) , 240-245
- https://doi.org/10.1002/nbm.1940020512
Abstract
For the validation of volume‐selective 1H and 31P NMR spectroscopy of the brain methods are required that allow high resolution quantitative mapping of tissue pH and metabolites on intact brain slices. The following techniques are proposed for this purpose. Tissue pH is imaged on cryostat sections of in situ frozen brains, using umbelliferone as a fluorescent pH indicator (Csiba et al, Brain Res 289, 334–337 (1983)). Regional tissue ATP content is measured in adjacent cryostat sections, using the luciferine/luciferase system of fireflies for evoking substrate‐specific bioluminescence (Kogure and Furones Alonso, Brain Res. 154, 273–284 (1978)). Lactate content is imaged in a similar way by inducing substrate‐specific bioluminescence with lactate dehydrogenase and luciferase from vibrio Fischeri (Paschen, J. Cereb. Blood Flow Metab. 5, 609–612 (1985)). The spatial resolution of these techniques is better than 100m̈, as exemplified in experimental brain tumors and brain infarct of cats. The applicability of biochemical mapping for the validation of NMR spectroscopy was tested in a global brain ischemia model of cat by correlating surface coil 31P and 1H spectra with the corresponding regional biochemical data, measured in the sensitive volume of the coil. Correlation coefficients were r = 0.907, 0.852 and 0.924 for pH, lactate and ATP, respectively. These results demonstrate that the biochemical measurements obtained by bioluminescence and fluoroscopic imaging correlate closely with the NMR data and, therefore, are appropriate for the validation of more complex applications, such as volume‐selective spectroscopy of brain infarcts or tumors.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of a newly discovered water suppression pulse sequence for high‐field in vivo1H surface coil NMR spectroscopyMagnetic Resonance in Medicine, 1989
- Combined 1H-MR Imaging and Localized 31P-Spectroscopy of Intracranial Tumors in 43 PatientsJournal of Computer Assisted Tomography, 1988
- Outer volume suppressed image related in vivo spectroscopy (OSIRIS), a high-sensitivity localization techniqueJournal of Magnetic Resonance (1969), 1988
- Spin-echo water suppression for the generation of pure-phase two-dimensional NMR spectraJournal of Magnetic Resonance (1969), 1987
- A comparison of some gradient-encoded volume-selection techniques forin vivo NMR spectroscopyMagnetic Resonance in Medicine, 1987
- Triple-Tracer Autoradiography of Cerebral Blood Flow, Glucose Utilization, and Protein Synthesis in Rat BrainJournal of Cerebral Blood Flow & Metabolism, 1986
- Regional Quantitative Determination of Lactate in Brain Sections. A Bioluminescent ApproachJournal of Cerebral Blood Flow & Metabolism, 1985
- Regional Quantitative Determination of Brain Glucose in Tissue Sections: A Bioluminescent ApproachJournal of Cerebral Blood Flow & Metabolism, 1985
- Multiparametric Imaging of Blood Flow and Metabolism after Middle Cerebral Artery Occlusion in CatsJournal of Cerebral Blood Flow & Metabolism, 1985
- Solvent suppression in fourier transform nuclear magnetic resonanceJournal of Magnetic Resonance (1969), 1983