An evaluation of the accuracy of flow measurements using magnetic resonance imaging (MRI)
- 1 January 1991
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 15 (4-5) , 170-176
- https://doi.org/10.3109/03091909109023704
Abstract
A study was undertaken to examine the accuracy and precision of the measurement of flow by magnetic resonance imaging (MRI) with consideration to the equipment and patient related parameters that might be encountered in vivo. For this purpose, test objects were devised consisting of PVC tubing, in which the internal diameter simulated the size of the arteries in the body. The design of the lest objects ensured that steady laminar flow was obtained in the sections being imaged. The calibration study suggests that, using MRI. flow can be measured in vitro with systematic error of better than 7·0 ± 5·0% and random error of better than 7·5%. In general, flow measurements obtained from MRI were found to correlate well with the known flows. However, the results indicated that there are prerequisite conditions for the validity of the measurements, such as the selection of appropriate flow pulse sequences and velocity limits. Measurements taken at vertically 40 mm away from the isocentre of the magnetic field -were significantly different (p < 0·01)This publication has 10 references indexed in Scilit:
- The measurement and visualisation of vessel blood flow by magnetic resonance imagingClinical Physics and Physiological Measurement, 1990
- The measurement of time-averaged flow by magnetic resonance imaging using continuous acquisition in the carotid arteries and its comparison with Doppler ultrasoundClinical Physics and Physiological Measurement, 1990
- Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US.Radiology, 1989
- Assessment of T1 time course changes and tissue-blood ratios after Gd-DTPA administration in brain tumorsMagnetic Resonance Imaging, 1988
- Demonstration of pulsatile cerebrospinal-fluid flow using magnetic resonance phase imagingThe British Journal of Radiology, 1987
- Measurement of aortic blood flow with MR imaging: comparative study with Doppler US.Radiology, 1987
- Use of standard gradients with compound oblique angulation for optimal quantitative MR flow imaging in oblique vesselsAmerican Journal of Roentgenology, 1987
- Time-of-flight MR flow imaging: selective saturation recovery with gradient refocusing.Radiology, 1986
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984