Autologous Blood Transfusion for Major Vascular Surgery Using the Sorenson Receptal Device
Open Access
- 1 August 1987
- journal article
- research article
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 15 (3) , 282-288
- https://doi.org/10.1177/0310057x8701500307
Abstract
Twenty-five patients having aortic surgery had blood scavenged using the Sorenson Receptal Device (Group A) and were compared with twenty-five patients having homologous blood transfusion (Group H). Mean intraoperative blood loss was similar in both groups, Group A 3224 (SD 2392) ml, Group H 2999 (SD 1579) ml, but the mean homologous blood replacement was significantly different intraoperatively, Group A 1.2 (SD 1.7) units, Group H 2.7 (SD 1.8) units. Total intra-hospital homologous blood replacement was not significantly different, Group A 4.0 (SD 3.4) units, Group H 5.5 (SD 5.8) units. Mean haemoglobin concentration in the scavenged blood was 8.5 (SD 2.1) g/dl compared to 10.8 (SD 2.4) g/dl in the median aged homologous blood units crossmatched for Group H. Mean red cell half life in the scavenged blood was the same as that for the homologous blood, 24 (SD 5) days, but plasma-free haemoglobin and bacterial contamination was greater in the scavenged blood. There was no difference in the incidence of postoperative renal dysfunction, coagulopathy or mortality between the two groups of patients.Keywords
This publication has 8 references indexed in Scilit:
- Autologous blood collection in abdominal vascular surgery. Assessment of a low pressure blood salvage system with particular reference to the preservation of cellular elements, triglyceride, complement and bacterial content in the collected bloodClinical and Laboratory Haematology, 2008
- The influence of autotransfusion on homologous blood requirements during aortic reconstructionCleveland Clinic Journal of Medicine, 1984
- Intraoperative autotransfusion during abdominal aortic reconstructionThe American Journal of Surgery, 1983
- Haemodilution for Major Vascular Surgery — Using 3.5% Polygeline (Haemaccel)Anaesthesia and Intensive Care, 1982
- Experiences with autotransfusion during abdominal aortic aneurysm resectionThe American Journal of Surgery, 1980
- Intraoperative autotransfusion in major vascular surgeryThe American Journal of Surgery, 1979
- Autotransfusion of blood contaminated by intestinal contentsJournal of the American College of Emergency Physicians, 1978
- Intraoperative Autotransfusion in Abdominal Aortic ResectionsArchives of Surgery, 1973