Three‐dimensional spiral fMRI technique: A comparison with 2D spiral acquisition
- 1 January 1998
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 39 (1) , 68-78
- https://doi.org/10.1002/mrm.1910390112
Abstract
A comparison study was performed of 3D and 2D spiral k‐space fMRI techniques using BOLD contrast with a 4.25‐min finger‐tapping task paradigm. The 3D sequence uses the conventional 2D spiral technique in conjunction with Fourier phase encoding in the slice select direction. Characteristics that were compared included image appearances, signal‐to‐noise ratio (SNR), fluctuation noise, functional contrast‐to‐noise ratio (fCNR), detected activation areas, inflow effect, and large vessel involvement. The results showed that, with constant total scan time, the 3D spiral acquisition has higher SNR and fCNR despite its slightly higher fluctuation noise. The capability for thin‐slice incoherent averaging is a further advantage of 3D over 2D. With these advantages as well as its intrinsic ability for contiguous slices and image reformatting, the 3D spiral fMRI technique may be superior to its 2D counterpart.Keywords
This publication has 33 references indexed in Scilit:
- Multi‐gradient echo with susceptibility inhomogeneity compensation (MGESIC): Demonstration of fMRI in the olfactory cortex at 3.0 TMagnetic Resonance in Medicine, 1997
- Commutator filter: A novel technique for the identification of structures producing significant susceptibility inhomogeneities and its application to functional MRIMagnetic Resonance in Medicine, 1996
- Fast 3D functional magnetic resonance imaging at 1.5 T with spiral acquisitionMagnetic Resonance in Medicine, 1996
- Quantitative assessment of blood inflow effects in functional MRI signalsMagnetic Resonance in Medicine, 1996
- In vivo measurement of blood oxygen saturation changes during motor activation using magnetic resonance imagingNeuroImage, 1996
- Functional connectivity in the motor cortex of resting human brain using echo‐planar mriMagnetic Resonance in Medicine, 1995
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Echo‐volume imagingMagnetic Resonance in Medicine, 1994
- Inflow versus deoxyhemoglobin effects in bold functional MRI using gradient echoes at 1.5 TNMR in Biomedicine, 1994
- Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)IEEE Transactions on Medical Imaging, 1991