Effect of Flow and Surface Conditions on Human Lymphocyte Isolation Using Microfluidic Chambers
- 16 November 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 20 (26) , 11649-11655
- https://doi.org/10.1021/la048047b
Abstract
Phenotypically pure subpopulations of lymphocytes can provide valuable insights into the immune response to injury and disease. The isolation of these subpopulations presents unique challenges, particularly when preprocessing incubation to attach fluorescent or antibody tags is to be minimized. This paper examines the separation of T and B lymphocytes from mixtures using microfluidic chambers coated with antibodies, focusing on flow conditions and surface chemistry. The adhesion of both cell types decreases as shear stress increases irrespective of the surface chemistry. The incorporation of poly(ethylene glycol) chains along with the antibodies on the chamber surface is shown to significantly improve the reproducibility of cell adhesion and is thus an important part of the overall system design. Furthermore, this technique is shown to be an effective way of isolating highly pure subpopulations of lymphocytes from model mixtures, even when the target cell concentration is low.Keywords
This publication has 17 references indexed in Scilit:
- Continuous Particle Separation Through Deterministic Lateral DisplacementScience, 2004
- Memory B Cells Specific for the NC16A Domain of the 180kDa Bullous Pemphigoid Autoantigen Can Be Detected in Peripheral Blood of Bullous Pemphigoid Patients and Induced In Vitro to Synthesize AutoantibodiesJournal of Investigative Dermatology, 2003
- Cell affinity separations using magnetically stabilized fluidized beds: Erythrocyte subpopulation fractionation utilizing a lectin-magnetite supportBiotechnology & Bioengineering, 2003
- A Microfabrication-Based Dynamic Array CytometerAnalytical Chemistry, 2002
- Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizingLab on a Chip, 2001
- Immunomagnetic cell sorting—pushing the limitsImmunotechnology, 1998
- Effect of Chain Density on Inhibition of Protein Adsorption by Poly(ethylene glycol) Based CoatingsJournal of Colloid and Interface Science, 1998
- Adsorption of proteins onto surfaces containing end-attached oligo(ethylene oxide): a model system using self-assembled monolayersJournal of the American Chemical Society, 1993
- Design and construction of a linear shear stress flow chamberAnnals of Biomedical Engineering, 1993
- Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at AurfacesScience, 1991