Leaf sequencing algorithms for segmented multileaf collimation
- 15 January 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (3) , 307-324
- https://doi.org/10.1088/0031-9155/48/3/303
Abstract
The delivery of intensity-modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation delivery. It is imperative that the fluence map delivered using the leaf sequence file is as close as possible to the fluence map generated by the dose optimization algorithm, while satisfying hardware constraints of the delivery system. Optimization of the leaf sequencing algorithm has been the subject of several recent investigations. In this work, we present a systematic study of the optimization of leaf sequencing algorithms for segmental multileaf collimator beam delivery and provide rigorous mathematical proofs of optimized leaf sequence settings in terms of monitor unit (MU) efficiency under most common leaf movement constraints that include minimum leaf separation constraint and leaf interdigitation constraint. Our analytical analysis shows that leaf sequencing based on unidirectional movement of the MLC leaves is as MU efficient as bidirectional movement of the MLC leaves.Keywords
This publication has 16 references indexed in Scilit:
- Improved leaf sequencing reduces segments or monitor units needed to deliver IMRT using multileaf collimatorsMedical Physics, 2001
- Intensity-modulated radiotherapy: current status and issues of interestInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Generation of discrete beam-intensity modulation by dynamic multileaf collimation under minimum leaf separation constraintsPhysics in Medicine & Biology, 1998
- Beam characteristics of a retrofitted double‐focused multileaf collimatorMedical Physics, 1998
- Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profilesPhysics in Medicine & Biology, 1998
- Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Realization and verification of three-dimensional conformal radiotherapy with modulated fieldsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- The design and performance characteristics of a multileaf collimatorPhysics in Medicine & Biology, 1994
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992