Four methods for identification of gram-negative nonfermenting rods: organisms more commonly encountered in clinical specimens
- 1 August 1980
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 12 (2) , 271-278
- https://doi.org/10.1128/jcm.12.2.271-278.1980
Abstract
Four commercial kits, Oxi/Ferm (OF), API 20E (AP), Minitek (MT; BBL Microbiology Systems) and Flow N/F (NF), were evaluated, without additional tests, for identification of 258 gram-negative nonfermentative rods. OF and MT were read after 48 h of incubation and AP and NF were read after 24 and 48 h of incubation, respectively. Overall, OF correctly identified 51% of strains, with 46% as part (but not first) of a spectrum of identifications (SI), and 3% incorrect species identification. MT yielded 85% correct identification, with 15% SI. Of 126 glucose-positive strains, or those with .gtoreq. 3 positive AP reactions after 24 h, 60% were correctly identified, with 40% SI; incubation for an additional 24 h raised the rate of correct identification to 99%, with 1% SI. A total of 132 strains yielded < 3 positive AP reactions after 24 h and were identified after 48 h only; of these, 82% were correctly identified, with 17% SI and 1% incorrect species identification. NF correctly identified 79% of cultures after 24 h, with 21% SI; corresponding figures after an additional 24 h of incubation were 80 and 20%, respectively. All 4 commercial methods show promise; OF is easiest to inoculate, but requires extra tests for optimal identification. AP reliably identifies the majority of clinically important nonfermenters, with fairly good species identification of saccharolytic strains after 24 h. MT yields reliable identification of most nonfermenters and has the advantage of flexibility. NF is easy to inoculate, yields satisfactory identification rates and may be read after 24 h of incubation.This publication has 16 references indexed in Scilit:
- Comparison of the API 20E and Oxi/Ferm systems in identification of nonfermentative and oxidase-positive fermentative bacteriaJournal of Clinical Microbiology, 1979
- Comparison of three methods for identifying nonfermenting gram-negative rodsCanadian Journal of Microbiology, 1978
- Evaluation of the API 20E system for identification of nonfermentative Gram-negative bacteriaJournal of Clinical Microbiology, 1978
- Evaluation of a Multitest System for Identification of Saccharolytic PseudomonadsAmerican Journal of Clinical Pathology, 1978
- Evaluation of two test-kits — API and Oxi Ferm tube — for identification of oxidative-fermentative gram-negative rodsMedical Microbiology and Immunology, 1977
- Rapid method for identification of gram-negative, nonfermentative bacilliJournal of Clinical Microbiology, 1976