Long-term Effects of Different Humidification Systems on Endotracheal Tube Patency
Open Access
- 1 April 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 100 (4) , 782-788
- https://doi.org/10.1097/00000542-200404000-00006
Abstract
Background: Accumulation of mucous secretions in an endotracheal tube (ETT) increases its resistance, and the amount of deposit may be affected by the quality of humidification and heating of the inspired gas. Methods: The authors assessed the impact of two humidification systems, a heated humidifier (HH) and a hygroscopic-hydrophobic heat and moisture exchanger (HME), on the ETT patency in patients selected to require mechanical ventilation for more than 48 h. This comparison was performed over two consecutive periods and used the acoustic reflection method, which characterizes the amount and site of ETT obstruction and allows estimating ETT inner volume and resistance. Measurements were performed three times a week over the period of mechanical ventilation. Comparisons were performed at mid duration and at the end of the mechanical ventilation period. Results: The HH was used in 34 patients, and the HME was used in 26 patients. The two groups had similar severity and duration of mechanical ventilation. At mid duration of mechanical ventilation (5.5 +/- 3.3 vs. 4.8 +/- 3.3 days; P = 0.4), no difference was observed in ETT volume and resistance between the two groups. At the end of the study period (10.5 +/- 5.8 vs. 9.6 +/- 6.3 days of mechanical ventilation; P = 0.4), ETT volume was reduced to a greater extent with HME than with HH (-3.3 +/- 2.9 vs. -5.1 +/- 2.5%; P = 0.008), and ETT resistance increased significantly more with the HME than with the HH (8.4 +/- 12.2 vs. 19.4 +/- 17.7%; P = 0.001). Conclusion: Prolonged use of humidification systems results in progressive reduction of ETT patency, and to a greater extent with HMEs than with HHs.Keywords
This publication has 33 references indexed in Scilit:
- Unfavorable mechanical effects of heat and moisture exchangers in ventilated patientsIntensive Care Medicine, 1997
- Gradual Reduction of Endotracheal Tube Diameter during Mechanical Ventilation via Different Humidification DevicesAnesthesiology, 1996
- Relationship between the humidity and temperature of inspired gas and the function of the airway mucosaCritical Care Medicine, 1996
- Performance Evaluation of Three Vaporizing Humidifiers and Two Heat and Moisture Exchangers in Patients with Minute Ventilation <10 L/minChest, 1992
- Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilationIntensive Care Medicine, 1992
- Complications of Acute Respiratory FailureAmerican Review of Respiratory Disease, 1988
- Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unitCritical Care Medicine, 1988
- A review of the mechanisms and methods of humidification of inspired gasesIntensive Care Medicine, 1988
- Humidity and the Anesthetized PatientAnesthesiology, 1979
- TEMPERATURE, HUMIDITY AND MUCUS FLOW IN THE INTUBATED TRACHEABritish Journal of Anaesthesia, 1974