SEC–viscometer detector systems. II. Resolution correction and determination of interdetector volume
- 5 March 1993
- journal article
- research article
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 47 (9) , 1701-1706
- https://doi.org/10.1002/app.1993.070470917
Abstract
The closely related topics of resolution correction and the determination of interdetector volume were examined. In determining the interdetector volume (δ) by searching to superimpose two types of intrinsic viscosity calibration curve (one from narrow standards and one from a broad standard), the underlying equation based upon symmetrical axial dispersion theory was derived. This equation combined with experimental results showed that the local intrinsic viscosity value is very similarly affected by interdetector volume and by band spreading. The result supported the idea of using an effective δ to effect an axial dispersion correction to local intrinsic viscosity data. However, it also increased the difficulty of finding both δ and standard deviation (δ) simultaneously by numerical search. Furthermore, attempts to apply the method to the chromatograms of narrow standards showed inadequate superposition. Following calculation of skewing factors, the superposition problems were attributed to skewing of the chromatograms of the monodisperse polymer standards used. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 12 references indexed in Scilit:
- SEC–viscometer detector systems. I. Calibration and determination of mark–houwink constantsJournal of Applied Polymer Science, 1993
- Data Interpretation for Coupled Molecular Weight Sensitive Detectors in Sec: Interdetector Transport TimeJournal of Liquid Chromatography, 1992
- Chemometrics in quantitative polymer analysis: Attempts to displace traditional methodsJournal of Applied Polymer Science, 1991
- Calibration of Separation and Instrumental Peak Broadening in Sec Coupled with Light Scattering of Simple PolymersJournal of Liquid Chromatography, 1990
- Quantitative Size Exclusion Chromatography: Assessing New DevelopmentsJournal of Liquid Chromatography, 1990
- Instrumental Broadening Correction in Size Exclusion Chromatography. Comparison of Several Deconvolution TechniquesJournal of Liquid Chromatography, 1990
- Characterization of complex polymer systems by size exclusion chromatography - homopolymers with long chain branching and copolymers with composition driftPublished by Walter de Gruyter GmbH ,1982
- High-Conversion Polymerization Kinetic Modeling Utilizing Gel Permeation ChromatographyPublished by American Chemical Society (ACS) ,1980
- Polymer reactors and molecular weight distribution. VIII. A method of interpreting skewed GPC chromatogramsJournal of Applied Polymer Science, 1969
- An analytical solution to Tung's axial dispersion equationJournal of Applied Polymer Science, 1969