Effect of processing time delay on the dose response of Kodak EDR2 film
- 23 July 2004
- journal article
- Published by Wiley in Medical Physics
- Vol. 31 (8) , 2284-2288
- https://doi.org/10.1118/1.1774111
Abstract
Kodak EDR2 film is a widely used two-dimensional dosimeter for intensity modulated radiotherapy (IMRT) measurements. Our clinical use of EDR2 film for IMRT verifications revealed variations and uncertainties in dose response that were larger than expected, given that we perform film calibrations for every experimental measurement. We found that the length of time between film exposure and processing can affect the absolute dose response of EDR2 film by as much as 4%-6%. EDR2 films were exposed to 300 cGy using 6 and 18 MV 10 x 10 cm2 fields and then processed after time delays ranging from 2 min to 24 h. An ion chamber measured the relative dose for these film exposures. The ratio of optical density (OD) to dose stabilized after 3 h. Compared to its stable value, the film response was 4%-6% lower at 2 min and 1% lower at 1 h. The results of the 4 min and 1 h processing time delays were verified with a total of four different EDR2 film batches. The OD/dose response for XV2 films was consistent for time periods of 4 min and 1 h between exposure and processing. To investigate possible interactions of the processing time delay effect with dose, single EDR2 films were irradiated to eight different dose levels between 45 and 330 cGy using smaller 3 x 3 cm2 areas. These films were processed after time delays of 1, 3, and 6 h, using 6 and 18 MV photon qualities. The results at all dose levels were consistent, indicating that there is no change in the processing time delay effect for different doses. The difference in the time delay effect between the 6 and 18 MV measurements was negligible for all experiments. To rule out bias in selecting film regions for OD measurement, we compared the use of a specialized algorithm that systematically determines regions of interest inside the 10 x 10 cm2 exposure areas to manually selected regions of interest. There was a maximum difference of only 0.07% between the manually and automatically selected regions, indicating that the use of a systematic algorithm to determine regions of interest in large and fairly uniform areas is not necessary. Based on these results, we recommend a minimum time of 1 h between exposure and processing for all EDR2 film measurements.Keywords
This publication has 22 references indexed in Scilit:
- Dose calculation accuracy of lung planning with a commercial IMRT treatment planning systemJournal of Applied Clinical Medical Physics, 2003
- Dosimetric accuracy of the ITP™ inverse treatment planning systemMedical Physics, 2002
- Rapid radiographic film calibration for IMRT verification using automated MLC fieldsMedical Physics, 2002
- Dosimetry of therapeutic photon beams using an extended dose range filmMedical Physics, 2002
- Dosimetric performance of an enhanced dose range radiographic film for intensity‐modulated radiation therapy quality assuranceMedical Physics, 2002
- Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimatorMedical Physics, 2002
- Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluationMedical Physics, 2002
- Variation of sensitometric curves of radiographic films in high energy photon beamsMedical Physics, 2001
- The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetryMedical Physics, 1999
- A new approach to film dosimetry for high energy photon beams: Lateral scatter filteringMedical Physics, 1997