Early and Late Phase Events Following Bioprosthetic Tricuspid Valve Replacement
- 1 September 1992
- journal article
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 7 (3) , 245-253
- https://doi.org/10.1111/j.1540-8191.1992.tb00809.x
Abstract
From 1961 through 1987, 9,247 patients underwent an intracardiac repair for valvular heart disease. Five hundred thirty patients had a procedure that included a tricuspid valve operation (6%), with tricuspid valve replacement performed in 175 patients (2%), of whom 154 had a bioprosthetic valve implanted (1.7%). These 154 patients with a bioprosthetic valve in the tricuspid position are the subject of this review. There were 27 males and 127 females. Ages ranged from 10 to 75 years. There was tricuspid valve insufficiency in 139 patients (90%), and stenosis plus insufficiency in 15 (10%). Carpentier-Edwards prostheses were implanted in 83 (54%), Ionescu-Shiley in 55 (35%), Hancock in 12 (8%), and Mitroflow in 4 (3%). Concomitant procedures were performed in 146 patients (95%). At least one previous operation had been performed in 86 patients (56%). Preoperatively, 139 patients were in functional Class III or IV (90%). Hospital death occurred in 20 patients (13%). Logistic regression analysis revealed that incremental risk factors for hospital death included increasing peripheral edema preoperatively (p = 0.04), and use of a Hancock prosthesis in the tricuspid position (p = 0.03). All 134 hospital survivors were followed at a mean of 66.01 months, range 1 to 162 months. There were 70 late deaths (52%). Log-rank test indicated that incremental risk factors for late death were: longer cross-clamp time at repair (p = 0.0007); higher pulmonary artery systolic pressure preoperatively (p = 0.01); earlier date of surgery (p = 0.03); and larger tricuspid prosthesis size (p = 0.06).(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 25 references indexed in Scilit:
- Tricuspid Valve Replacement in ChildrenThe Annals of Thoracic Surgery, 1987
- Predictors of survival after tricuspid valve surgeryThe American Journal of Cardiology, 1984
- Comparison of late (62 to 140 months) degenerative changes in simultaneously implanted and explanted mitral valve positions in six patientsThe American Journal of Cardiology, 1984
- Long-term results of tricuspid valve replacement and the problem of prosthetic valve thrombosisThe American Journal of Cardiology, 1983
- Structural changes in porcine xenografts used as substitute cardiac valves: Gross and histologic observations in 51 glutaraldehyde-preserved Hancock valves in 41 patientsThe American Journal of Cardiology, 1977
- Surgical Treatment of Aneurysms of the Ascending AortaScandinavian Journal of Thoracic and Cardiovascular Surgery, 1977
- Thrombotic jamming of a tricuspid prosthesis.Heart, 1976
- Malfunction of Bjork-Shiley valve prosthesis in tricuspid position.Heart, 1976
- Late thrombosis of Starr-Edwards tricuspid ball valve prosthesisThe American Journal of Cardiology, 1974
- Late Thrombotic Obstruction of Starr-Edwards Tricuspid Valve ProsthesisChest, 1972