Three‐dimensional time‐of‐flight MR angiography with a specialized gradient head coil
- 1 March 1993
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 3 (2) , 365-375
- https://doi.org/10.1002/jmri.1880030212
Abstract
A gradient head coil has been developed, incorporating two independent gradients within the conventional body coil of the magnetic resonance (MR) system, with reduced rise times (200 μsec) and maximum amplitudes of 37 and 18 mT/m in the z and y directions, respectively. This gradient coil was systematically evaluated by testing two-dimensional (2D) and three-dimensional (3D) time-of-flight (TOF) MR angiography sequences applied to a pulsatile flow phantom simulating a carotid stenosis and the intracranial vasculature. When standard 2D and 3D TOF MR angiography techniques were used to image the carotid stenosis model, dramatic signal loss in the stenotic segment and a large flow void distal to the stenosis were seen. The shorter (3.8 msec) absolute echo times (TEs) achievable with the gradient coil in 3D sequences substantially reduced the phase dispersion and associated signal loss in the region of stenosis. Shorter TEs alone (3.2 msec) did not minimize signal loss, and firstorder flow compensation in the read and section-select directions provided further improvements (despite slightly longer TEs). Reduction of TEs in 2D sequences yielded relatively poor results regardless of the refocusing scheme or TE. This study confirms the predicted benefits of a dedicated coil with improved gradient capabilities for 3D MR angiography. The study suggests the limitations of 2D TOF MR angiography in the evaluation of severe stenoses.Keywords
This publication has 14 references indexed in Scilit:
- Carotid artery stenosis: clinical efficacy of two-dimensional time-of-flight MR angiography.Radiology, 1992
- Detection of internal carotid artery stenosis: comparison of MR angiography, color Doppler sonography, and arteriography.Radiology, 1992
- 3DFT MR angiography of the carotid bifurcation: potential and limitations as a screening examination.Radiology, 1991
- Safety considerations in MR imaging.Radiology, 1990
- Volume MR angiography: methods to achieve very short echo times.Radiology, 1990
- Acoustic analysis of gradient-coil noise in MR imaging.Radiology, 1989
- Three-dimensional (volume) gradient-echo imaging of the carotid bifurcation: preliminary clinical experience.Radiology, 1989
- Intracranial circulation: pulse-sequence considerations in three-dimensional (volume) MR angiography.Radiology, 1989
- Reduction of T2* dephasing in gradient field-echo imaging.Radiology, 1989
- In-plane vascular imaging: pulse sequence design and strategy.Radiology, 1988