In-plane vascular imaging: pulse sequence design and strategy.
- 1 March 1988
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 166 (3) , 875-882
- https://doi.org/10.1148/radiology.166.3.3340788
Abstract
Magnetic resonance (MR) angiography is a noninvasive method of obtaining images without contrast agents. Recent developments in sequence design have allowed images of moving spins to be obtained without a loss of signal by rephasing the spins with three or four gradient pulses to compensate for constant velocity or acceleration, respectively. At longer echo times (TE), this approach allowed for low readout gradients and high signal-to-noise ratios. Angiograms with a resolution of 300 .mu.m were obtained. With additional sequences that allow some dephasing but minimal signal loss, separate images of arteries and veins were obtained. Phase information was used to estimate flow velocity. Application of the rephasing scheme to gradient-echo sequences allowed for ungated, fast MR angiograms. Acceleration correction was important for long TE sequences, but velocity-corrected, gradient-echo sequences with a very short TE were comparable to velocity- and acceleration-corrected, gradient-echo sequences with slightly longer TEs. With ungated three-dimensional, gradient-echo sequences, susceptibility artifacts were minimized and excellent contrast-to-noise ratios were obtained.This publication has 14 references indexed in Scilit:
- MR gated subtraction angiography: evaluation of lower extremities.Radiology, 1986
- Rapid NMR imaging of dynamic processes using the FLASII techniqueMagnetic Resonance in Medicine, 1986
- Projective MRI angiography and quantitative flow‐volume densitometryMagnetic Resonance in Medicine, 1986
- Projective Imaging of Pulsatile Flow with Magnetic ResonanceScience, 1985
- MR Velocity Imaging by Phase DisplayJournal of Computer Assisted Tomography, 1985
- Blood flow: magnetic resonance imaging.Radiology, 1985
- Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method.Radiology, 1985
- Visualization and Measurement of Flow with Magnetic Resonance Imaging. Darstellung und Messung von Flußgeschwindigkeit mit bildgebender KernresonanzBiomedizinische Technik/Biomedical Engineering, 1985
- NMR Even Echo Rephasing in Slow Laminar FlowJournal of Computer Assisted Tomography, 1984
- NMR rheotomography: Feasibility and clinical potentialMedical Physics, 1982