Internal Ventricular Defibrillation with Sequential Pulse Countershock in Pigs: Comparison with Single Pulses and Effects of Pulse Separation
- 1 May 1987
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 10 (3) , 497-502
- https://doi.org/10.1111/j.1540-8159.1987.tb04512.x
Abstract
We compared single to sequential pulse shocks with different pulse separations on internal cardiac defibrillation by using a catheter and plaque electrodes in open-chest halothane-anesthetized pigs. Ten seconds after fibrillation onset, defibrillation was attempted using trapezoidal pulses of 65% tilt, approximately 5 ms duration and fixed outputs from 1.0 to 50 joules (J). With single pulses, minimum defibrillation energy for the catheter alone was 2.4 +/- 0.3 J/kg (mean +/- standard error) and 2.1 +/- 0.2 J/kg for the catheter tip to plaque configuration. With sequential pulse shocks, the first pulse delivered via the catheter and the second pulse from the catheter tip to the plaque electrode, the energy necessary for defibrillation was dependent on the separation time between the two pulses (2.0 +/- 0.2, 1.5 +/- 0.2, 0.9 +/- 0.1, 1.3 +/- 0.3, 0.6 +/- 0.2, and 1.2 +/- 0.2 J/kg at 100, 10, 1, 0.5, 0.2, and 0.1 ms, respectively). Further, at the 0.2 ms separation, 100% of the animals could be defibrillated with less than 2.0 J/kg (35 J total). We conclude that sequential pulse defibrillation provides a significant improvement over single pulse defibrillation. The optimum separation between the sequential pulses in this study was 0.2 ms.Keywords
This publication has 16 references indexed in Scilit:
- Improved internal defibrillation with twin pulse sequential energy delivery to different lead orientations in pigsThe American Journal of Cardiology, 1985
- Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration.Circulation, 1984
- Pacing threshold changes after transvenous catheter countershockThe American Journal of Cardiology, 1984
- Role of a catheter lead system for transvenous countershock and pacing during electrophysiologic tests: An assessment of the usefulness of catheter shocks for terminating ventricular tachyarrhythmiasThe American Journal of Cardiology, 1983
- Treatment of malignant ventricular tachyarrhythmias with the automatic implantable defibrillatorInternational Journal of Cardiology, 1983
- Low energy counterchock using an intravascular catheter in an acute cardiac care settingThe American Journal of Cardiology, 1982
- Ventricular defibrillation in the dog with a bielectrode intravascular catheterArchives of internal medicine (1960), 1973
- Feasibility and Effectiveness of Low-Energy Catheter Defibrillation in ManCirculation, 1973
- TRANSVENOUS AUTOMATIC DEFIBRILLATOR — PRELIMINARY CLINICAL TESTS OF ITS DEFIBRILLATING SUBSYSTEMAsaio Journal, 1972
- Transthoracic ventricular defibrillation in the dog with unidirectional rectangular double pulsesCardiovascular Research, 1970