Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, nonocclusive roller pumps and centrifugal pumps
- 1 January 1999
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 14 (1) , 3-10
- https://doi.org/10.1177/026765919901400102
Abstract
Cardiopulmonary bypass (CPB) involves the use of either an occlusive roller pump or centrifugal pump. Damage to blood elements, including haemolysis, may arise from occlusion when using a roller pump; the appropriate degree of occlusion has not yet been determined scientifically. Centrifugal and nonocclusive roller pumps are reputed to reduce haemolysis. The objective of this study was to compare haemolysis caused by a standard roller pump with a dynamically set nonocclusive roller pump and with a centrifugal pump. We prospectively randomized 60 patients undergoing routine coronary artery surgery into three groups: standard roller pump (STD, n = 20), dynamically set roller pump (DYN, n = 20), or centrifugal pump (CEN, n = 20). The level of plasma free haemoglobin (FHb) was measured preoperatively, and the rate of formation of FHb (in mg/dl/min) was determined at the end of the ischaemic phase and at the end of CPB. Cardiotomy suction blood was isolated for the ischaemic phase and returned before the end of CPB. It was found that there were no differences between the groups in demographic or operative variables. The rate of formation of FHb at the end of the ischaemic phase was similar for all groups (STD 0.108 ± 0.10, DYN 0.117 ± 0.08, CEN 0.129 ± 0.07). At the end of CPB, after return of the cardiotomy suction blood, there was a significant (<0.001) increase in the rate of formation of FHb in all groups. The increase was similar for each of the groups (STD 0.424 ± 0.17, DYN 0.481 ± 0.20, CEN 0.471 ± 0.18). We conclude that the rates of haemolysis are similar for each of the pump types, and no benefit is conferred by the use of either a dynamically set roller pump or a centrifugal pump compared with the standard roller pump. The return of the cardiotomy suction blood to the circulation is the principal source of plasma free haemoglobin.Keywords
This publication has 12 references indexed in Scilit:
- Differences in blood activation related to roller/centrifugal pumps and heparin coated/uncoated surfaces in a cardiopulmonary bypass model circuitPerfusion, 1996
- Roller and centrifugal pumps compared in vitro with regard to haemolysis, granulocyte and complement activationPerfusion, 1994
- Pump-induced haemolysis: is the constrained vortex pump better or worse than the roller pump?Perfusion, 1992
- Vortex pumping for routine cardiac surgery: a comparative studyPerfusion, 1990
- Hemolysis during cardiopulmonary bypassJournal of Cardiothoracic Anesthesia, 1989
- Cellular aggregation and trauma in cardiotomy suction systems.Thorax, 1979
- Use of Tetramethylbenzidine in Plasma Hemoglobin AssayClinical Chemistry, 1977
- The Role of Haptoglobin in the Clearance and Distribution of Extracorpuscular HemoglobinBlood, 1961
- Studies on the Serum Haptoglobin Level in Hemoglobinemia and Its Influence on Renal Excretion of HemoglobinBlood, 1957