Test-Retest Reliability of Swept Visual Evoked Potential Measurements of Infant Visual Acuity and Contrast Sensitivity
- 1 April 2004
- journal article
- Published by Springer Nature in Pediatric Research
- Vol. 55 (4) , 701-708
- https://doi.org/10.1203/01.pdr.0000113769.44799.02
Abstract
The aim of the study was to describe variations in swept visual evoked potential (SWEEP-VEP) assessment of visual acuity and contrast sensitivity in infants and to evaluate the best way to estimate visual performance from obtained SWEEP-VEP data. The visual performance of 92 infants (6–40 wk of age) was measured in two separate visits. Results were verified with repeated tests in seven adults. There was a strong association between the two measurements of infant visual acuity (r = 0.91, p < 0.001), with no constant bias and an inter-assay coefficient of variation of 8.4%. The intra-assay coefficient of variation was 17% and in repeated sessions all obtained acuity measures were normally distributed, indicating that the mean and not the maximum threshold best estimates visual acuity. This estimate of visual acuity also had lower test-retest variability than those calculated from the maximum threshold or threshold from the average EEG signals (p = 0.001). Test-retest measures of infant contrast sensitivity had a correlation coefficient of 0.72 (p < 0.001) and an inter-assay coefficient of variation of 23%. With the observed test-retest variability, SWEEP-VEP is less valid for estimating the visual performance of individual subjects, but it can give reliable group means. This method was well suited to describe visual development in the infants, which for acuity as well as contrast sensitivity increased by 0.64 octave per doubling in age. However, the variability of the SWEEP-VEP method can be a limiting factor, for example, in the assessment of the potential effect of dietary docosahexaenoic acid in a homogeneous group of infants.Keywords
This publication has 28 references indexed in Scilit:
- The essentiality of long chain n-3 fatty acids in relation to development and function of the brain and retinaProgress in Lipid Research, 2001
- Dietary essential fatty acids, long-chain polyunsaturated fatty acids, and visual resolution acuity in healthy fullterm infants: a systematic reviewEarly Human Development, 2000
- Infant vision and retinal function in studies of dietary long-chain polyunsaturated fatty acids: methods, results, and implicationsThe American Journal of Clinical Nutrition, 2000
- A Critical Appraisal of the Role of Dietary Long-Chain Polyunsaturated Fatty Acids on Neural Indices of Term Infants: A Randomized, Controlled TrialPediatrics, 2000
- Visual Acuity and the Essentiality of Docosahexaenoic Acid and Arachidonic Acid in the Diet of Term InfantsPediatric Research, 1998
- Effect of Formula Supplemented with Docosahexaenoic Acid andγ-Linolenic Acid on Fatty Acid Status and Visual Acuity in Term InfantsJournal of Pediatric Gastroenterology and Nutrition, 1998
- The role of long chain polyunsaturated fatty acids (LCPUFA) in neonatal nutritionActa Paediatrica, 1998
- Docosahexaenoic acid and the development and function of the infant retinaCurrent Opinion in Lipidology, 1997
- Visual Acuity, Erythrocyte Fatty Acid Composition, and Growth in Term Infants Fed Formulas with Long Chain Polyunsaturated Fatty Acids for One YearPediatric Research, 1997
- Are long-chain polyunsaturated fatty acids essential nutrients in infancy?The Lancet, 1995