X-Ray Dose Reduction in Fluoroscopically Guided Electrophysiology Procedures
- 1 March 2006
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 29 (3) , 262-271
- https://doi.org/10.1111/j.1540-8159.2006.00332.x
Abstract
This study assessed the efficacy of a new dose reduction regime in fluoroscopically guided electrophysiology (EP) procedures, which included diagnostic electrophysiological investigations, radiofrequency ablation, and biventricular pacing. A modified dose regime for fluoroscopy was implemented in one of our cardiac electrophysiology laboratories. The x-ray system was programmed with a hierarchy of three fluoroscopy doses, and therefore image quality and settings. The default (lowest) dose mode was not expected to be suitable for all patient sizes or for the entirety of all procedures. Staff raised the dose level in a stepped manner as and when required to optimize the imaging requirements of the procedure. Phantom studies indicated that the low dose mode provided adequate image quality for visualizing EP catheters, while significantly lowering patient skin dose. In 52 clinical cases, questionnaires were used to assess the subjective clinical image quality. The mean image quality score for the low dose setting was rated between "adequate" and "good." The fluoroscopy dose level was raised from the lowest level for 6% of the total fluoroscopy time. Procedural Dose Area Product (DAP) meter readings were analyzed for patients prior to (n = 85) and after (n = 150) the implementation of the low dose regime and showed an overall reduction in DAP rate of 74%. The hierarchical dose regime proved to be acceptable in routine clinical practice for EP procedures, leading to significant reductions in patient doses.Keywords
This publication has 20 references indexed in Scilit:
- Reference Values for Diagnostic Radiology: Application and ImpactRadiology, 2005
- Radiation Exposure During Catheter Ablation of Atrial FibrillationCirculation, 2004
- Application of low dose rate pulsed fluoroscopy in cardiac pacing and electrophysiology: patient dose and image quality implicationsThe British Journal of Radiology, 2004
- Barium enema: use of increased copper filtration to optimize dose and image qualityThe British Journal of Radiology, 2004
- Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac proceduresThe British Journal of Radiology, 2003
- Fluoroscopy: Patient Radiation Exposure IssuesRadioGraphics, 2001
- Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat‐panel imagers (AMFPIs) for diagnostic radiologyMedical Physics, 1997
- Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopyThe British Journal of Radiology, 1995
- Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.Circulation, 1994
- The influence of tube filtration and potential on patient dose during X-ray examinationsPhysics in Medicine & Biology, 1988