Contrast-enhanced 3D MRA using SENSE
Top Cited Papers
- 1 November 2000
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 12 (5) , 671-677
- https://doi.org/10.1002/1522-2586(200011)12:5<671::aid-jmri3>3.0.co;2-f
Abstract
Sensitivity encoding (SENSE) was used to improve the performance of three-dimensional contrast-enhanced magnetic resonance angiography (3D CE-MRA). Utilizing an array of receiver coils for sensitivity encoding, the encoding efficiency of gradient-echo imaging was increased by factors of up to three. The feasibility of the approach was demonstrated for imaging of the abdominal vasculature. On the one hand, using a SENSE reduction factor of two, the spatial resolution of a breath-hold scan of 17 seconds was improved to 1.0 x 2.0 x 2.0 mm(3). On the other hand, using threefold reduction, time-resolved 3D CE-MRA was performed with a true temporal resolution of 4 seconds, at a spatial resolution of 1.6 x 2.1 x 4.0 mm(3). CE-MRA with SENSE was performed in healthy volunteers and patients and compared with a standard protocol. Throughout, diagnostic quality images were obtained, showing the ability of sensitivity encoding to enhance spatial and/or temporal resolution considerably in clinical angiographic examinations.Keywords
This publication has 20 references indexed in Scilit:
- Contrast-enhanced MR angiography of the carotid bifurcationJournal of Magnetic Resonance Imaging, 1999
- Optimized visualization of vessels in contrast enhanced intracranial MR angiographyMagnetic Resonance in Medicine, 1998
- Renal MR angiography: A comprehensive approachJournal of Magnetic Resonance Imaging, 1998
- Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography.Radiology, 1997
- Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.Radiology, 1996
- Breath-hold, contrast-enhanced, three-dimensional MR angiography.Radiology, 1996
- The effects of time varying intravascular signal intensity and k‐space acquisition order on three‐dimensional MR angiography image qualityJournal of Magnetic Resonance Imaging, 1996
- Three-dimensional gadolinium-enhanced MR angiography for aortoiliac inflow assessment plus renal artery screening in a single breath hold.Radiology, 1996
- Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.Radiology, 1995
- Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriographyJournal of Magnetic Resonance Imaging, 1993