Measuring blood cholesterol outside the pathology laboratory: issues of accuracy and reliability
- 1 June 1991
- journal article
- research article
- Published by Wiley in Australian Journal of Public Health
- Vol. 15 (2) , 142-146
- https://doi.org/10.1111/j.1753-6405.1991.tb00324.x
Abstract
Desk‐top analysers that are simple to use, portable and free from technical requirements are now widely used for blood cholesterol measurement outside the traditional pathology laboratory setting. Test accuracy and reliability are essential if these portable desk‐top analysers are to be of value in the assessment and management of elevated blood cholesterol. To determine their accuracy and reliability we compared the results obtained from four different desk‐top analysers with those from a teaching hospital's routine laboratory method. The desk‐top analysers assessed were the Ames Minilab, the Kodak DT60, the Boehringer Reflotron and the Abbott Vision. The precision of each desk‐top analyser was within acceptable limits, defined as a coefficient of variation less than 5 per cent. The results from the Vision, Reflotron and DT60 related closely to those from the routine laboratory method, with least squares linear regression slopes ranging from 0.92 to 1.06 and intra‐class correlation coefficients from 0.95 to 0.99. The Minilab showed least agreement with the routine laboratory method and caution should be taken in the interpretation of cholesterol estimations made with this device.Keywords
This publication has 13 references indexed in Scilit:
- Reliability of the Reflotron in the determination of cholesterolScandinavian Journal of Clinical and Laboratory Investigation, 1990
- Blood cholesterol concentration: fingerstick plasma vs venous serum samplingClinical Chemistry, 1990
- Accuracy and precision of analyses for total cholesterol as measured with the Reflotron cholesterol method.Clinical Chemistry, 1989
- Testing Cholesterol AccuracyPublished by American Medical Association (AMA) ,1988
- How accurately does the Reflotron dry‐chemistry system measure plasma total cholesterol levels when used as a community‐screening device?The Medical Journal of Australia, 1988
- Comparison of Reflotron and laboratory cholesterol measurementsThe Medical Journal of Australia, 1988
- Is Relationship Between Serum Cholesterol and Risk of Premature Death From Coronary Heart Disease Continuous and Graded?JAMA, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986