Gas Chromatographic/Matrix Isolation/Fourier Transform Infrared Spectra of the Laterally Chlorinated Dibenzo-p-Dioxins and Dibenzofurans
- 1 November 1989
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 43 (8) , 1317-1324
- https://doi.org/10.1366/0003702894204263
Abstract
Reference-quality gas chromatographic/matrix isolation/Fourier transform infrared spectra have been recorded for the following fifteen compounds, which collectively are referred to as the “laterally” chlorinated dibenzo- p-dioxins and dibenzofurans: 2,3,7,8-tetrachlorodibenzo- p-dioxin (2,3,7,8-TCDD); 1,2,3,7,8-pentachlorodibenzo- p-dioxin (1,2,3,7,8-PeCDD);l,2,3,4,7,8-hexachlorodibenzo- p-dioxin(1,2,3,4,7,8-HxCDD)>; 1,2,3,6,7,8,-hexachlorodibenzo- p-dioxin(1,2,3,6,7,8-HxCDD); 1,2,3,7,8,9-hexachlorodibenzo- p-dioxin (1,2,3,7,8,9-HxCDD); 1,2,3,4,6,7,8-heptachlorodibenzo- p-dioxin (1,2,3,4,6,7,8-HpCDD); 2,3,7,8-tetrachlorodibenzofuran (2,3,7,8-TCDF); 1,2,3,7,8-pentachlorodibenzofuran (1,2,3,7,8-PeCDF); 2,3,4,7,8-pentachlorodibenzofuran (2,3,4,7,8-PeCDF); 1,2,3,4,7,8-hexachlorodibenzofuran(1,2,3,4,7,8-HxCDF); 1,2,3,6,7,8-hexachlorodibenzofuran (1,2,3,6,7,8-HxCDF); 1,2,3,7,8,9-hexachlorodibenzofuran (1,2,3,7,8,9-HxCDF); 2,3,4,6,7,8-hexachlorodibenzofuran (2,3,4,6,7,8-HxCDF); 1,2,3,4,6,7,8-heptachlorodibenzofnran (1,2,3,4,6,7,8-HpCDF); and 1,2,3,4,7,8,9-heptachlorodibenzofuran (1,2,3,4,7,8,9-HpCDF). These spectra are discussed qualitatively and, for the laterally chlorinated dioxins, are compared to previously recorded gas-phase GC/FT-IR spectra. Estimates of the instrumental detection limits for these compounds, using matrix isolation GC/FT-IR spectroscopy, were found to fall in the mid-to-high picogram and low nanogram ranges.Keywords
This publication has 24 references indexed in Scilit:
- Applications of gas chromatography-Fourier transform IR spectrometry in environmental analysesTrAC Trends in Analytical Chemistry, 1989
- Pentachlorodibenzo-p-dioxin Isomer Differentiation by Capillary Gas Chromatography Fourier Transform Infrared SpectroscopyApplied Spectroscopy, 1988
- Molecular Geometry Approximations for Chlorinated Dibenzodioxins by Fourier Transform Infrared SpectroscopyApplied Spectroscopy, 1988
- Dioxin-like effects observed in male rats following exposure to octachlorodibenzo-p-dioxin (OCDD) during a 13-week study*1Toxicology and Applied Pharmacology, 1988
- HPLC Separation and FT-IR Isomer Differentiation of the 1,2,4,7/1,2,4,8-Tetrachlorodibenzodioxin Isomer Pair—A Theoretical/Empirical Approach to Dibenzodioxin Isomer AssignmentApplied Spectroscopy, 1988
- Tetrachlorodibenzo-p-Dioxin Isomer Differentiation by Capillary Gas Chromatography Fourier Transform-Infrared SpectroscopyApplied Spectroscopy, 1987
- Application of gas chromatography/matrix-isolation/Fourier transform infrared spectrometry to dioxin determinationsAnalytical Chemistry, 1986
- Tetrachlorodibenzodioxin isomer differentiation by micro diffuse reflectance Fourier transform infrared spectrometry at the low nanogram levelAnalytical Chemistry, 1985
- High-resolution gas chromatography/matrix isolation infrared spectrometryAnalytical Chemistry, 1985
- GC/Matrix Isolation/FTIR Applications: Analysis of PCBsJournal of Chromatographic Science, 1985