On the influence of training data quality in k‐t BLAST reconstruction
Open Access
- 26 October 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1175-1183
- https://doi.org/10.1002/mrm.20256
Abstract
This work investigated how the quality of prior information (i.e., data acquired during the training stage) influences k-t BLAST reconstruction. The impact of several factors, such as the amount of training data, the presence of spatial misregistration in the training data, and the effects of filtering, was investigated with simulations and in vivo data. It is shown that k-t BLAST outperforms sliding window reconstruction, even with very limited training data. By increasing the amount of training data, reconstruction error continues to decrease, albeit by a diminishing amount. However, an increased amount of training data also increases susceptibility to misregistration of the training data. Filtering of the training data with the goal of reducing truncation artifacts had only minor impact on reconstruction errors. Considering the balance among obtaining the most benefit from the training data, minimizing susceptibility to misregistration, and keeping data acquisition to a minimum, it is concluded that in cardiac imaging the training datasets should be limited to 10–20 profiles in k-space for a typical field of view. The training data may be acquired in a separate breathhold without much penalty, if care is taken to minimize misregistration, such as with a navigator. Magn Reson Med 52:1175–1183, 2004.Keywords
This publication has 9 references indexed in Scilit:
- k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlationsMagnetic Resonance in Medicine, 2003
- Using UNFOLD to remove artifacts in parallel imaging and in partial‐Fourier imagingMagnetic Resonance in Medicine, 2002
- Cardiac MRI: Recent progress and continued challengesJournal of Magnetic Resonance Imaging, 2002
- On the UNFOLD methodMagnetic Resonance in Medicine, 2001
- Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)†Magnetic Resonance in Medicine, 2001
- Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRIMagnetic Resonance in Medicine, 1999
- Optimal scan for time-varying tomography. I. Theoretical analysis and fundamental limitationsIEEE Transactions on Image Processing, 1995
- Optimal scan for time-varying tomography. II. Efficient design and experimental validationIEEE Transactions on Image Processing, 1995
- Spatial Registration of Multispectral and Multitemporal Digital Imagery Using Fast Fourier Transform TechniquesIEEE Transactions on Geoscience Electronics, 1970