Evaluation of NucliSens easyMAG for Automated Nucleic Acid Extraction from Various Clinical Specimens
- 1 February 2007
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 45 (2) , 421-425
- https://doi.org/10.1128/jcm.00894-06
Abstract
The objectives of this study were to evaluate the performance of the NucliSens easyMAG platform for nucleic acid extraction from different clinical specimens compared to NucliSens miniMAG platform and manual QIAGEN extraction. The NucliSens easyMAG and the NucliSens miniMAG showed equal performance on 215 throat swabs since real-time nucleic acid sequence-based amplification scored the same samples positive for Mycoplasma pneumoniae (n = 9) and Chlamydia pneumoniae (n = 5) RNAs, although internal control RNA was slightly better detected with the NucliSens easyMAG (99.3% versus 96.8%). NucliSens easyMAG extracted nucleic acids more efficiently (higher recovery and/or fewer inhibitors) compared to QIAGEN extraction by showing, on average, lower Ct values in real-time LightCycler PCR, although 4 individual specimen out of 45 were found positive only with QIAGEN. For nine M. pneumoniae-positive throat swabs, the mean difference in Ct values between NucliSens easyMAG extraction and QIAGEN extraction was −2.26 (range, −5.77 to +0.60); for the detection of five C. pneumoniae-positive throat swabs, the average difference in Ct values between the two methods was −3.38 (range, −6.62 to −2.02); and for the detection of cytomegalovirus in 24 blood samples, the mean difference in Ct values between the two methods was −0.95 (range, −5.51 to +1.68). The NucliSens easyMAG is considerably easier to perform, efficiently extracts nucleic acids from throat swabs and whole blood, is automated, and has high throughput.Keywords
This publication has 26 references indexed in Scilit:
- Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation KitJournal of Clinical Microbiology, 2005
- Isolation and Detection of Enterovirus RNA from Large-Volume Water Samples by Using the NucliSens miniMAG System and Real-Time Nucleic Acid Sequence-Based AmplificationApplied and Environmental Microbiology, 2005
- Immunohistostaining Assays for Detection of Chlamydia pneumoniae in Atherosclerotic Arteries Indicate Cross-Reactions with Nonchlamydial Plaque ConstituentsJournal of Clinical Microbiology, 2004
- Comparison of Automated and Manual Nucleic Acid Extraction Methods for Detection of Enterovirus RNAJournal of Clinical Microbiology, 2003
- Comparison of Commercial DNA Extraction Kits for Extraction of Bacterial Genomic DNA from Whole-Blood SamplesJournal of Clinical Microbiology, 2003
- Development and Verification of an Automated Sample Processing Protocol for Quantitation of Human Immunodeficiency Virus Type 1 RNA in PlasmaJournal of Clinical Microbiology, 2003
- Detection of Mycoplasma pneumoniae in Spiked Clinical Samples by Nucleic Acid Sequence-Based AmplificationJournal of Clinical Microbiology, 2002
- Development of a Genomics-Based PCR Assay for Detection of Mycoplasma pneumoniae in a Large Outbreak in New York StateJournal of Clinical Microbiology, 2001
- Detection of Mycoplasma pneumoniae by Two Polymerase Chain Reactions and Role of M. pneumoniae in Acute Respiratory Tract Infections in Pediatric PatientsThe Journal of Infectious Diseases, 1996
- Clinical utility of the polymerase chain reaction to diagnose Mycoplasma pneumoniae infectionPathology, 1995