Design of a portable near infrared system for topographic imaging of the brain in babies
- 1 October 2004
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (10) , 3276-3283
- https://doi.org/10.1063/1.1775314
Abstract
A portable topographic near-infrared spectroscopic (NIRS) imaging system has been developed to provide real-time temporal and spatial information about the cortical response to stimulation in unrestrained infants. The optical sensing array is lightweight, flexible, and easy to apply to infants ranging from premature babies in intensive care to children in a normal environment. The sensor pad consists of a flexible double-sided circuit board onto which are mounted multiple sources (light-emitting diodes) and multiple detectors ( photodiodes), all electrically encapsulated in silicone rubber. The control electronics are housed in a box with a medical grade isolated power supply and linked to a PC fitted with a data acquisition card, the signal acquisition and analysis being performed using LABVIEW™. The signal output is displayed as an image of oxy- and deoxyhemoglobin concentration ( , [Hb]) changes at a frame rate of . Experiments have been conducted on phantoms to determine the sensitivity of the system, and the results have been compared to theoretical simulations. The system has been tested in volunteers by imaging changes in forearm muscle oxygenation, following blood pressure cuff occlusion to obtain typical [Hb] and plots.
Keywords
This publication has 35 references indexed in Scilit:
- Wavelength dependence of the precision of noninvasive optical measurement of oxy‐, deoxy‐, and total‐hemoglobin concentrationMedical Physics, 2001
- On-line optical imaging of the human brain with 160-ms temporal resolutionOptics Express, 2000
- A 32-channel time-resolved instrument for medical optical tomographyReview of Scientific Instruments, 2000
- Optical tomography in medical imagingInverse Problems, 1999
- Multichannel photon counting instrument for spatially resolved near infrared spectroscopyReview of Scientific Instruments, 1999
- Sources of phase noise in homodyne and heterodyne phase modulation devices used for tissue oximetry studiesReview of Scientific Instruments, 1998
- Precision localization of hidden absorbers in body tissues with phased-array optical systemsReview of Scientific Instruments, 1996
- Experimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomographyOptics Letters, 1995
- Application of the finite-element method for the forward and inverse models in optical tomographyJournal of Mathematical Imaging and Vision, 1993
- A design for a stable and reproducible phantom for use in near infra-red imaging and spectroscopyPhysics in Medicine & Biology, 1993