Use of advanced breast biopsy instrumentation while performing stereotactic breast biopsies: review of 150 consecutive biopsies1
- 1 July 2000
- journal article
- review article
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 191 (1) , 9-15
- https://doi.org/10.1016/s1072-7515(00)00294-5
Abstract
Background: Stereotactic breast biopsies are being performed in the United States with increasing frequency. Advanced breast biopsy instrumentation (ABBI) is a recent addition to the list of available stereotactic breast biopsy devices (eg, fine-needle aspiration, automated needle cores, and vacuum-assisted devices). Indications for the ABBI procedure in the management of patients with nonpalpaple mammographic lesions have not been established. Study Design: Prospectively collected data on 150 patients biopsied with the ABBI procedure were reviewed. Results: From April 1996 to May 1997, 150 patients with indeterminate or suspicious nonpalpable mammographic lesions were biopsied using the ABBI technique. Complications were minor. One patient (0.6%) required a repeat biopsy because of insufficient tissue and one patient had repeat excision to confirm the diagnosis of atypical ductal hyperplasia. Cancer was diagnosed in 26%. Followup mammograms were obtained in 94% of the patients. Lesions were missed in three patients (2%), none of whom were later found to have cancer. One patient (0.6%) required a repeat ABBI biopsy for postbiopsy architectural distortion. Postprocedure mammographic scarring was otherwise minimal and was noted in only 16% of the patients. Of the 111 patients with benign diagnoses, 67 were seen for clinical followup; 98% had good cosmetic outcomes and were satisfied with the ABBI technique. Conclusions: The ABBI technique is a safe, reliable stereotactic breast biopsy technique that is well accepted by patients. The sensitivity and specificity of ABBI biopsy for the diagnosis of carcinoma in this series were each 100% for the 142 patients returning for followup. Indications for the technique are similar to those for traditional needle localization excisional breast biopsies.Keywords
This publication has 13 references indexed in Scilit:
- Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun.American Journal of Roentgenology, 1999
- Stereotactic Automated Surgical Biopsy Using the ABBI Biopsy Device: A Multicenter StudyThe Breast Journal, 1998
- Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device.Radiology, 1997
- Stereotactic core-needle biopsy of the breast: a report of the Joint Task Force of the American College of Radiology, American College of Surgeons, and College of American PathologistsCA: A Cancer Journal for Clinicians, 1997
- Cost-effectiveness of stereotactic core needle biopsy: analysis by means of mammographic findings.Radiology, 1997
- Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: improved accuracy with directional, vacuum-assisted biopsy.Radiology, 1997
- Nondiagnostic stereotaxic core breast biopsy: results of rebiopsy.Radiology, 1996
- Stereotaxic core biopsy of breast carcinoma: accuracy at predicting invasion.Radiology, 1995
- STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONSThe Lancet, 1989
- Cytologic Diagnosis of Occult Breast Lesions Using Stereotaxic Needle AspirationArchives of Surgery, 1987