Temporal stability of twenty-four-hour ambulatory hemodynamic bioimpedance measures in African American adolescents
- 1 August 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 9 (4) , 173-177
- https://doi.org/10.1097/00126097-200408000-00001
Abstract
The reliability of ambulatory impedance cardiography has not been evaluated. The purpose of this study was to determine the reproducibility of daytime and night-time ambulatory bioimpedance-derived measures of hemodynamic function in youth. Thirty-five African American adolescents (ages 16.2±1.4 years, 14 girls, 21 boys) with high normal systolic resting blood pressure (BP) were evaluated twice, separated by a 2-month interval. Measures were collected using the AIM-8-V3 Wearable Cardiac Performance Monitor (Bio-impedance Technology, Inc., Chapel Hill, North Carolina, USA) and the Spacelabs ambulatory BP monitor 90207 (Spacelabs Inc., Redmond, Washington, USA) from 0600 h to midnight every 20 min and from midnight to 0600 h every 30 min in the natural environment. There were no significantly different means (P>0.15) between the two visits for daytime ambulatory heart rate (HR, r = 0.81), stroke volume (SV, r = 0.54), cardiac output (CO, r = 0.56), pre-ejection period (PEP, r = 0.59), left ventricular ejection time (LVET, r = 0.74), Heather Index (HI, r = 0.79), systolic BP (SBP, r = 0.79), diastolic BP (DBP, r = 0.66), mean arterial pressure (MAP, r = 0.65) and total peripheral resistance (TPR, r = 0.47). Overall means for night-time ambulatory HR (r = 0.76), SV (r = 0.49), CO (r = 0.45), LVET (r = 0.43), HI (r = 0.82), SBP (r = 0.65), DBP (r = 0.62), MAP (r = 0.63) and TPR (r = 0.20) were not significantly different between visits (P > 0.06). Mean differences (P < 0.01) were observed for PEP (r = 0.57). The findings demonstrate that across 2 months in youth daytime and night-time ambulatory bioimpedance-derived measures of HR, HI, SBP, DBP and MAP are highly repeatable and SV, CO, PEP and LVET are moderately repeatable. This methodology should prove useful in cardiovascular research and clinical care.Keywords
This publication has 30 references indexed in Scilit:
- Large-scale ensemble averaging of ambulatory impedance cardiogramsBehavior Research Methods, Instruments & Computers, 2003
- Reproducibility of Cardiac Output Measurements by Doppler Echocardiography in Prepubertal Children and AdultsInternational Journal of Sports Medicine, 2001
- New ambulatory impedance cardiograph validated against the Minnesota Impedance CardiographPsychophysiology, 2001
- Ambulatory monitoring of the impedance cardiogramPsychophysiology, 1996
- Pressor Reactivity, Ethnicity, and 24-Hour Ambulatory Monitoring in Children from Hypertensive FamiliesBehavioral Medicine, 1994
- Factors affecting ambulatory blood pressure reproducibility. Results of the HARVEST Trial. Hypertension and Ambulatory Recording Venetia Study.Hypertension, 1994
- Noninvasive assessment of cardiac output in children using impedance cardiographyAmerican Heart Journal, 1990
- Hemodynamics of Blood Pressure Responses During Active and Passive CopingPsychophysiology, 1990
- Methodological Guidelines for Impedance CardiographyPsychophysiology, 1990
- Race and gender influence ambulatory blood pressure patterns of adolescents.Hypertension, 1989