Superparamagnetic iron oxide-enhanced MR imaging: pulse sequence optimization for detection of liver cancer.
- 1 August 1989
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 172 (2) , 393-397
- https://doi.org/10.1148/radiology.172.2.2748820
Abstract
The effects of magnetic resonance (MR) pulse sequences and timing parameters on tumor-liver contrast were studied in an animal model of metastatic liver cancer. Six spin-echo (SE), three inversion-recovery (IR), and four gradient-echo (GRE) sequences were evaluated at 0.6 T before and after injection of super-paramagnetic iron oxide. GRE techniques, irrespective of echo time and flip angle, showed the greatest change in signal intensity (enhancement) of the liver after administration of iron oxide. Single-acquisition GRE sequences (16 seconds) matched the contrast-to-noise ratio (C/N) performance of the most effective 6.4-minute SE sequences. Multiexcitation GRE sequences showed tumor-liver C/Ns per unit time that were significantly (P less than .05) higher than those achieved with SE and IR sequences. GRE sequences, which recruit intravoxel dephasing as an additional source of transverse relaxation enhancement (T2*), show a higher C/N per unit time and in this respect seem superior to SE and IR sequences for MR imaging with superparamagnetic iron oxide.This publication has 16 references indexed in Scilit:
- Hepatic metastases: randomized, controlled comparison of detection with MR imaging and CT.Radiology, 1987
- Transverse relaxation of solvent protons induced by magnetized spheres: Application to ferritin, erythrocytes, and magnetiteMagnetic Resonance in Medicine, 1987
- Motion artifact reduction with fast spin-echo imaging.Radiology, 1987
- Liver metastasis detection: comparative sensitivities of MR imaging and CT scanning.Radiology, 1987
- Ferrite particles: a superparamagnetic MR contrast agent for enhanced detection of liver carcinoma.Radiology, 1987
- Optimal pulse sequence for imaging hepatic metastases.Radiology, 1986
- Optimal pulsing sequences for MR contrast agentsAmerican Journal of Roentgenology, 1986
- Dynamic spin-echo MRI of liver cancer using Gadolinium-DTPA: animal investigationAmerican Journal of Roentgenology, 1986
- Detection of hepatic metastases: analysis of pulse sequence performance in MR imaging.Radiology, 1986
- Pulse sequence optimization for MR imaging using a paramagnetic hepatobiliary contrast agent.Radiology, 1985