Insertable Loop Recorder Use for Detection of Intermittent Arrhythmias
- 4 May 2004
- journal article
- review article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (5) , 657-664
- https://doi.org/10.1111/j.1540-8159.2004.00502.x
Abstract
The advent of prolonged monitoring with the implanted loop recorders has revolutionized the quest for detection of elusive infrequent arrhythmias in patients with unexplained syncope. The capability of prolonged monitoring has permitted us to obtain symptom rhythm correlation in the majority of patients suspected to have underlying infrequent arrhythmia. The implanted loop recorder is easily implanted in the left pectoral region with a minimally invasive procedure, providing at least 14 months of continuous monitoring that is both patient and automatically activated. Several recent studies suggest that it plays a major role in patients with infrequent symptoms and suspected arrhythmia, including patients with syncope and conduction disturbances, mild to moderate underlying heart disease, and atypical epilepsy. In a randomized trial, the device was found to be cost-effective and improved diagnostic yield compared to conventional tilt and electrophysiological testing. Wider application of prolonged monitoring is ongoing, including assessment of ventricular arrhythmias, atrial fibrillation, and conduction disturbances. The implantable loop recorder is most useful in patients with infrequent unexplained syncope when noninvasive testing is negative.Keywords
This publication has 32 references indexed in Scilit:
- Comparison of automatic and patient-activated arrhythmia recordings by implantable loop recorders in the evaluation of syncopeThe American Journal of Cardiology, 2003
- Selective use of diagnostic tests inpatients with syncope of unknown causeJournal of the American College of Cardiology, 2003
- Syncope: is a diagnosis a diagnosis?**Editorials published in the Journal of the American College of Cardiologyreflect the views of the authors and do not necessarily represent the views of JACCor the American College of Cardiology.Journal of the American College of Cardiology, 2003
- Incidence and Prognosis of SyncopeNew England Journal of Medicine, 2002
- Implantable loop recorder undersensing mimicking complete heart blockEP Europace, 2002
- An welcher Stelle soll ein implantierbarer EKG-Event-Recorder plaziert werden?Clinical Research in Cardiology, 2000
- Final results from a pilot study with an implantable loop recorder to determine the etiology of syncope in patients with negative noninvasive and invasive testingThe American Journal of Cardiology, 1998
- Maturation of the Sensed Electrogram Amplitude Over Time in a New Subcutaneous Implantable Loop RecorderPacing and Clinical Electrophysiology, 1997
- The Etiology of Syncope in Patients With Negative Tilt Table and Electrophysiological TestingCirculation, 1995
- Evaluation and Outcome of Patients with SyncopeMedicine, 1990