Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Top Cited Papers
- 8 May 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 115 (18) , 2426-2434
- https://doi.org/10.1161/circulationaha.106.658237
Abstract
Background— Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. Methods and Results— Since January 2004, patients presenting with very late stent thrombosis (>1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for ≥2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630±166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9±16.0 versus 13.3±7.9 mm; P P P P 2 ; P =0.46) but significantly larger for the in-stent segment (28.6±11.9 versus 20.1±6.7 mm 2 ; P =0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P 2 ; P =0.03) in patients with very late stent thrombosis compared with controls. Conclusions— Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.Keywords
This publication has 22 references indexed in Scilit:
- Very late thrombosis after drug‐eluting stentsCatheterization and Cardiovascular Interventions, 2006
- Correlates and Long-Term Outcomes of Angiographically Proven Stent Thrombosis With Sirolimus- and Paclitaxel-Eluting StentsCirculation, 2006
- Late Incomplete Stent Apposition After Sirolimus-Eluting Stent Implantation: A Serial Intravascular Ultrasound AnalysisJournal of the American College of Cardiology, 2005
- Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantationJournal of the American College of Cardiology, 2005
- Incomplete Stent Apposition After Implantation of Paclitaxel-Eluting Stents or Bare Metal StentsCirculation, 2005
- Incidence, Mechanism, Predictors, and Long-Term Prognosis of Late Stent Malapposition After Bare-Metal Stent ImplantationCirculation, 2004
- Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting StentCirculation, 2004
- Regional Remodeling as the Cause of Late Stent MalappositionCirculation, 2003
- Background Incidence of Late Malapposition After Bare-Metal Stent ImplantationCirculation, 2002
- Predictors and outcomes of stent thrombosis. An intravascular ultrasound registryEuropean Heart Journal, 2002