Patellar tracking measurement in the normal knee
- 1 January 1995
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 13 (1) , 115-122
- https://doi.org/10.1002/jor.1100130117
Abstract
Eleven fresh frozen cadaveric knee specimens were mounted in a knee kinematics test device, and normal patellar movements were evaluated with use of an external device for direct measurement of patellar movements. The effects of four different measurement conditions were assessed through alteration of one condition and determination of its effect on patellar kinematics with the use of six specimens. The four conditions included (a) change of the measuring axis from an axis parallel to the central axis of the femur (femoral axis) to one parallel to the central axis of the tibia (tibial axis), (b) rotation of the femoral axis internally 6°, (c) change of the direction of the quadriceps force from parallel to the mechanical line of the lower extremity to a direction parallel to the femoral shaft, and (d) increase of the magnitude of the quadriceps force from 111 to 500 N. During knee flexion, the patella shifted laterally after a slight initial medial shift, tilted laterally from midflexion to 90°, and gradually rotated medially. The patellar shift relative to the tibial axis appeared to be more medial than the shift measured relative to the femoral axis; the discrepancy was caused by the valgus position of the tibia relative to the femur. Changing the rotational angle of the femoral axis artifically changed the patellar position. Varying the direction of the quadriceps within the narrow range and increasing the quadriceps force did not affect patellar movements. It is likely that the anatomic configuration of the patella allows the patella to seat in a stable configuration so that it resists moderate changes in the load and direction of the quadriceps. Tibial rotation exerted a major influence on patellar shift and tilt in the early phase of knee flexion: the patella rotated medially when the tibia was externally rotated and rotated laterally when the tibia was internally rotated. These results indicate that the patella may be unstable in the first phase of knee flexion when the tibia is rotated.Keywords
This publication has 10 references indexed in Scilit:
- The Effects of Axial Rotational Alignment of the Femoral Component on Knee Stability and Patellar Tracking in Total Knee Arthroplasty Demonstrated on Autopsy SpecimensClinical Orthopaedics and Related Research, 1993
- Patellar Tilt and Subluxation in Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1993
- The Effect of Patellar Button Placement and Femoral Component Design on Patellar Tracking in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1992
- The Effect of Femoral Component Position on Patellar Tracking After Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1990
- The three‐dimensional tracking pattern of the human patellaJournal of Orthopaedic Research, 1990
- Patellofemoral DisordersPublished by Wolters Kluwer Health ,1984
- Patellar Pain and IncongruencePublished by Wolters Kluwer Health ,1983
- Biomechanics of the Patello-Femoral Joint. Part I: A Study of the Contact and the Congruity of the Patello-Femoral Compartment and Movement of the PatellaEngineering in Medicine, 1983
- Patellar TrackingPublished by Wolters Kluwer Health ,1981
- Patellar tracking patterns measurement by analytical X-ray photogrammetryJournal of Biomechanics, 1979