Abstract
Langmuir probe measurements have been carried out which confirm the occurrence of double-layers in an argon positive column. Pulsing the discharge current permitted probe measurements to be performed in the presence of the double- layer. Supplementary evidence, obtained from d.c. and pulsed discharges, indicated that the double-layers formed in the two modes of operation were similar. The double-layers observed were weak and stable; their relation to other classes of double-layers is discussed, and directions for future work are suggested.Keywords
This publication has 17 references indexed in Scilit:
- Strong laboratory double layers in the presence of a magnetic fieldPhysics Letters A, 1979
- Formation of Double Layers in Laboratory PlasmasPublished by Springer Nature ,1979
- A double layer reviewAstrophysics and Space Science, 1978
- The double sheath associated with a hot cathodeProceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1976
- Theory of a steady-state nonisothermal positive column in a magnetic fieldJournal of Applied Physics, 1973
- An investigation into the mechanisms occurring in the discharge of an ion sourcePlasma Physics, 1973
- Moving StriationsPublished by Elsevier ,1968
- Structure of the Double Sheath in a Hot-Cathode PlasmaJournal of Applied Physics, 1965
- A General Theory of the Plasma of an ArcPhysical Review B, 1929
- The Interaction of Electron and Positive Ion Space Charges in Cathode SheathsPhysical Review B, 1929