Frequency-place compression and expansion in cochlear implant listeners
- 1 November 2004
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (5) , 3130-3140
- https://doi.org/10.1121/1.1804627
Abstract
In multichannel cochlear implants, low frequency information is delivered to apical cochlear locations while high frequency information is delivered to more basal locations, mimicking the normal acoustic tonotopic organization of the auditory nerves. In clinical practice, little attention has been paid to the distribution of acoustic input across the electrodes of an individual patient that might vary in terms of spacing and absolute tonotopic location. In normal-hearing listeners, Başkent and Shannon (J. Acoust. Soc. Am. 113, 2003) simulated implant signal processing conditions in which the frequency range assigned to the array was systematically made wider or narrower than the simulated stimulation range in the cochlea, resulting in frequency-place compression or expansion, respectively. In general, the best speech recognition was obtained when the input acoustic information was delivered to the matching tonotopic place in the cochlea with least frequency-place distortion. The present study measured phoneme and sentence recognition scores with similar frequency-place manipulations in six Med-El Combi 40+ implant subjects. Stimulation locations were estimated using the Greenwood mapping function based on the estimated electrode insertion depth. Results from frequency-place compression and expansion with implants were similar to simulation results, especially for postlingually deafened subjects, despite the uncertainty in the actual stimulation sites of the auditory nerves. The present study shows that frequency-place mapping is an important factor in implant performance and an individual implant patient’s map could be optimized with functional tests using frequency-place manipulations.Keywords
This publication has 17 references indexed in Scilit:
- Speech recognition under conditions of frequency-place compression and expansionThe Journal of the Acoustical Society of America, 2003
- The effects of short-term training for spectrally mismatched noise-band speechThe Journal of the Acoustical Society of America, 2003
- Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implantThe Journal of the Acoustical Society of America, 2002
- Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implantsThe Journal of the Acoustical Society of America, 2001
- Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearingThe Journal of the Acoustical Society of America, 1999
- Simulating the effect of cochlear-implant electrode insertion depth on speech understandingThe Journal of the Acoustical Society of America, 1997
- Speech Recognition with Primarily Temporal CuesScience, 1995
- Acoustic characteristics of American English vowelsThe Journal of the Acoustical Society of America, 1995
- Development of the Hearing In Noise Test for the measurement of speech reception thresholds in quiet and in noiseThe Journal of the Acoustical Society of America, 1994
- A cochlear frequency-position function for several species—29 years laterThe Journal of the Acoustical Society of America, 1990