Improved accuracy of the occlusion technique for assessing total respiratory compliance in infants
- 1 March 1987
- journal article
- Published by Wiley in Pediatric Pulmonology
- Vol. 3 (2) , 71-77
- https://doi.org/10.1002/ppul.1950030206
Abstract
The occlusion technique to measure total respiratory system compliance (Cocc) was used in 28 sedated infants with a variety of cardiopulmonary diseases and 14 anaesthetised infants during the first 2 years of life. In this report, we describe some of the potential problems in the technique and how to avoid them. Invalidation of the occlusion technique because of consistent failure to relax during brief airway occlusions occurred in only four of 42 infants despite the fact that only four infants were studied during the first month of life and 17 were between 12 and 26 months old. The technique was invalidated in two intubated infants because of persistent leaks around the endotracheal tube. In the remaining 36 infants, data sometimes had to be excluded as a result of instability of end‐expiratory volume, intermittent leaks, or failure to relax during occlusions performed at low lung volumes or during inspiration. However, by performing 15–25 occlusions per infant, it was possible to obtain sufficient reliable data for accurate analysis of Cocc in all these infants. Providing that the potential errors and limitations of the occlusion technique are recognized, it appears to be applicable to a wide range of healthy and sick infants. Pediatr Pulmonol 1987; 3:71–77.Keywords
This publication has 19 references indexed in Scilit:
- Comparison of the occlusion and inflation techniques for measuring total respiratory compliance in sick, intubated infantsPediatric Pulmonology, 1987
- The accuracy of esophageal pressure measurements in convalescent and sick intubated infantsPediatric Pulmonology, 1986
- Airway and lung receptors and their reflex effects in the newbornPediatric Pulmonology, 1985
- Single-breath measurement of lung mechanics in very low birth weight infantsCritical Care Medicine, 1985
- Pulmonary compliance in sick low birthweight infants. How reliable is the measurement of oesophageal pressure?Archives of Disease in Childhood, 1983
- Location and discharge properties of respiratory vagal afferents in the newborn dogRespiration Physiology, 1982
- Functional localization of pulmonary stretch receptors in the tracheobronchial tree of the kittenCanadian Journal of Physiology and Pharmacology, 1982
- Respiratory Compliance of Newborns after Birth and Its Prognostic Value for the Course and Outcome of Respiratory DiseaseRespiration, 1982
- Lung reflexes in rabbits during pulmonary stretch receptor block by sulphur dioxideRespiration Physiology, 1978
- Effect of premature delivery on the maturation of the Hering-Breuer inspiratory inhibitory reflex in human infantsThe Journal of Pediatrics, 1976