Mobility and Contact Mechanics of a Rotating Platform Total Knee Replacement
- 1 November 2001
- journal article
- Published by Wolters Kluwer Health
- Vol. 392 (392) , 24-37
- https://doi.org/10.1097/00003086-200111000-00004
Abstract
Despite their increasing clinical use, mobile-bearing total knee replacements have not been well characterized biomechanically. An experimental and finite element analysis was done to assess the mobility and contact mechanics of a widely used rotating platform total knee replacement. Parameters that varied were axial load, condylar load allocation, flexion angle, and static versus dynamic loading. Similar results from the physical model and finite element model lend credence to the validity of the findings. The torque required to initiate rotation (static torque) was greater than that to sustain rotation (dynamic torque). At four times body weight axial load, peak resisting torque measured was 9.47+/-0.61 and 5.51+/-0.38 N-m, for static and dynamic torque, respectively. A 60-40 condylar load allocation produced slightly less resisting torque than the 50-50 load. For all practical purposes, the polyethylene insert rotated simultaneously with the femoral component, leading to maintenance of high contact area, desirable behavior clinically. Walking cycle simulations produced a total axial rotation range of motion of 6 degrees. The high frictional torques observed at the mobile interface may explain why a percentage of these mobile-bearings fail to rotate under routine functional load.Keywords
This publication has 22 references indexed in Scilit:
- Mobile-Bearing Knee ReplacementJournal of Bone and Joint Surgery, 2000
- Cemented Rotating-Platform Total Knee ReplacementJournal of Bone and Joint Surgery, 2000
- Survivorship Analysis of Cementless Meniscal Bearing Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1997
- Adaptiive finite element modeling of long‐term polyethylene wear in total hip arthroplastyJournal of Orthopaedic Research, 1996
- Three-dimensional kinematics of the human knee during walkingJournal of Biomechanics, 1992
- Long-Term Survivorship Analysis of Cruciate-Sparing Versus Cruciate-Sacrificing Knee Prostheses Using Meniscal BearingsClinical Orthopaedics and Related Research, 1990
- Measurement of lower extremity kinematics during level walkingJournal of Orthopaedic Research, 1990
- A three-dimensional kinematic and dynamic model of the lower limbJournal of Biomechanics, 1989
- Normative data of knee joint motion and ground reaction forces in adult level walkingJournal of Biomechanics, 1983
- Wear characteristics of UHMW polyethylene: A method for accurately measuring extremely low wear ratesJournal of Biomedical Materials Research, 1978