Adaptiive finite element modeling of long‐term polyethylene wear in total hip arthroplasty
- 1 July 1996
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 14 (4) , 668-675
- https://doi.org/10.1002/jor.1100140424
Abstract
Adaptive remeshing capability was addded to an existing sliding‐distance‐coupled finite element model of polyethylene wear in total hip arthroplasty. This augmentation allowed earlier postoperative wear simulation to be extended to the clinically more significant long‐term regimen (as long as 20 years). Loads and femoral head excursions were taken from a physically validated gait analysis model of a patient with an instrumented total hip replacement. For otherwise identical 22, 28, and 32 mm components, the least volumetric wear but the most linear wear occurred for the 22 mm head. When the polyethylene thickness in a 22 mm component was reduced to the same as that in a 32 mm component, the volumetric wear rate for the 22 mm component was still much less than that for the larger component, indicating that sliding distance (head size). rather than polyethylene liner thickness, was primarily responsible for the difference in rates, A “28 mm” series, for which head sizes were varied across the range of currently accepted industrial tolerances, showed that although initial wear rates were greatest for the least congruent articulations, the long‐term volumetric wear was nearly the same, regardless of initial clearance.Keywords
This publication has 16 references indexed in Scilit:
- A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplastyJournal of Biomechanics, 1996
- Numerical instabilities in bone remodeling simulations: The advantages of a node-based finite element approachJournal of Biomechanics, 1995
- Comparison of hip force calculations and measurements in the same patientThe Journal of Arthroplasty, 1994
- Quality of the Surface Finish of the Head of the Femoral Component and the Wear Rate of the Socket in Long-Term Results of the Charnley Low-Friction ArthroplastyProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1992
- Tribology of Total Artificial JointsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1991
- Effect of femoral head size on wear of the polyethylene acetabular component.Journal of Bone and Joint Surgery, 1990
- Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads.Journal of Bone and Joint Surgery, 1989
- Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: III: The measurement of internal volume changes in explanted Charnley sockets after 2–16 years in vivo and the determination of wear factorsWear, 1985
- Contact pressure dependence of wear rates of ultra high molecular weight polyethyleneJournal of Biomedical Materials Research, 1979
- Contact and Rubbing of Flat SurfacesJournal of Applied Physics, 1953