Abstract
Two MRA techniques were evaluated for the follow-up of coiled intracranial aneurysms. Twenty-nine coiled aneurysms were evaluated for a total of 36 follow-up assessments using 3D time-of flight MRA (TOF MRA), an auto-triggered elliptic–centric-ordered three-dimensional gadolinium-enhanced MR angiogram (ATECO MRA), as well as a selective digital subtraction angiography (DSA), which served as the “gold standard”. Confident visualization was seen in 36 (100%) of ATECO MRAs and in 32 (89%) of the TOF MRAs. Eleven residual aneurysm components (RACs) greater than 2 mm were described on DSA. Of these, nine were seen on ATECO MRA (sensitivity of 81% and specificity of 88%) and four were seen on TOF MRA (sensitivity of 40% and specificity of 90%). The two RACs not seen on ATECO MRA both measured 3 mm. The six RACs not seen on TOF MRA measured 3, 4 and 5 mm. ATECO MRA provides a non-invasive reliable angiogram for the surveillance of coiled aneurysms and is superior to TOF MRA for this purpose.Keywords
This publication has 30 references indexed in Scilit:
- Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiographyNeuroradiology, 2003
- The impact of the International Subarachnoid Aneurysm Treatment Trial (ISAT) on neurosurgical practiceActa Neurochirurgica, 2003
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Spinal Dural Arteriovenous Fistula Localization with a Technique of First-Pass Gadolinium-enhanced MR Angiography: Initial ExperienceRadiology, 2002
- MR angiography in the follow-up of coiled cerebral aneurysms after treatment with guglielmi detachable coilsActa Radiologica, 2002
- Endovascular Treatment of Unruptured AneurysmsStroke, 2001
- Intracranial Arteriovenous Malformations: Real-Time Auto-triggered Elliptic Centric-ordered 3D Gadolinium-enhanced MR Angiography—Initial AssessmentRadiology, 2001
- Follow-up of Intracranial Aneurysms Treated with Detachable Coils: Comparison of Gadolinium-enhanced 3D Time-of-Flight MR Angiography and Digital Subtraction AngiographyRadiology, 2001
- Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patientsJournal of Neurosurgery, 1997
- The effects of time varying intravascular signal intensity and k‐space acquisition order on three‐dimensional MR angiography image qualityJournal of Magnetic Resonance Imaging, 1996