Theoretical analysis of in vivo macrophage adhesion and foreign body giant cell formation on strained poly(etherurethane urea) elastomers
- 1 July 1994
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 28 (7) , 819-829
- https://doi.org/10.1002/jbm.820280709
Abstract
Quantitative description of foreign body giant cell (FBGC) formation on poly(etherurethane urea) (PEUU) surfaces as a function of time can conceivably predict the effects of polymer characteristics on cellular responses in vivo. In the present study, the formation of FBGCs on strained and unstrained PEUUs was quantified with two parameters: the density of adherent macrophages present initially that participate in FBGC formation (do) and the rate constant for cell fusion (k); both kinetic parameters were used to calculate the time‐dependent FBGC density (dfc). Relationships were sought between results of the cellular analysis and the extent of environmental stress cracking (ESC), as characterized by scanning electron microscopy. Surface degradation was semiquantified with percent light transmittance.The materials used were: base PEUU, base PEUU with 1% Santowhite® antioxidant powder, base PEUU with 5% Methacrol 2133F® antifume agent, and base PEUU with both 1% Santowhite® and Methacrol 2138F®. A comparison of unstrained base PEUU with base PEUU strained to 400% elongation indicated that the rate of cell fusion, but not do and dfc, increased in the presence of strain. In all strained samples, additives that strongly affected the ESC also influenced FBGC kinetic parameters. Strained PEUU containing Santowhite® had the lowest do, the slowest rate of cell fusion, and lowest dfc, and the least incidence of ESC. The results suggest that the incidence of ESC in PEUU was decreased in the presence of Santowhite®, which also lowered the number of adherent macrophages participating in FBGC formation, the rate of FBGC formation and the subsequent FBGC density. These studies also indicate that strain in PEUUs does not directly modulate the adherent macrophage and FBGC density. Further studies are necessary to delineate the relationship between PEUU strain and adherent macrophage and FBGC activation, which leads to the exocytosis of degrading agents and the observed incidence of biodegradation. © 1994 John Wiley & Sons, Inc.Keywords
This publication has 29 references indexed in Scilit:
- Evaluation of soft tissue response to a poly[urethane urea]Biomaterials, 1992
- Exudation of proliferative macrophages in local inflammation in the peritoneumJournal of Leukocyte Biology, 1992
- Theoretical analysis on cell size distribution and kinetics of foreign‐body giant cell formation in vivo on polyurethane elastomersJournal of Biomedical Materials Research, 1992
- Foreign‐body giant cells and polyurethane biostability: In vivo correlation of cell adhesion and surface crackingJournal of Biomedical Materials Research, 1991
- Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80AJournal of Biomedical Materials Research, 1990
- Inflammatory Response to ImplantsAsaio Journal, 1988
- The Relationship between Fusion and Proliferation in Mouse Alveolar Macrophages*Endocrinology, 1987
- Biomaterial biocompatibility and the macrophageBiomaterials, 1984
- In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogelJournal of Biomedical Materials Research, 1983
- THE PRODUCTION OF FOREIGN BODY GIANT CELLS IN VITROThe Journal of Experimental Medicine, 1912