Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A
- 1 May 1990
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 24 (5) , 621-637
- https://doi.org/10.1002/jbm.820240508
Abstract
The phenomenon of stress cracking of Pellethane 2363‐80A (PEU) was investigated using the cage implant system. A cytotoxic polyvinylchloride (PVC) and a silicone rubber containing an anti‐inflammatory steroid were used to create inflammatory environments in which the biostability of the pre‐stressed PEU was tested. These coimplants provided alternative in vivo environments to study in vivo polymer interactions. The inflammatory responses to the implanted cages were monitored by analyzing the exudates aspirated from the cages at different implantation times over 21 days. The pre‐stressed PEU specimens were retrieved after 5, 10, and 15 weeks postimplantation and examined by optical microscopy (OM) and scanning electron microscopy (SEM). The results support the conclusion that in vivo cracking of stressed (strained) Pellethane 80A is related to cell–polymer interactions. Severe cracking or rupture of the implanted PEU specimens was observed as early as 5 weeks postimplantation. Molecular chain degradation of the implanted specimens was evident from molecular weight measurements. Neither surface cracking nor degradation of macromolecules was found on the pre‐stressed PEU specimens with the added cytotoxic PVC implanted over 15 weeks. No cracking was observed on the pre‐stressed specimens in the presence of steroid silicone rubber, even after 10 weeks implantation.This publication has 11 references indexed in Scilit:
- Polyether Polyurethanes: Biostable or Not?Journal of Biomaterials Applications, 1988
- The Use of Silicone/Polyurethane Graft Polymers as a Means of Eliminating Surface Cracking of Polyurethane ProsthesesJournal of Biomaterials Applications, 1988
- In vivo leucocyte interactions with the NHLBI-DTB primary reference materials: Polyethylene and silica-free polydimethylsiloxaneBiomaterials, 1987
- Cell Adhesion and Interactions with BiomaterialsThe Journal of Adhesion, 1986
- In vivo biocompatibility studies. VII. Inflammatory response to polyethylene and to a cytotoxic polyvinylchlorideJournal of Biomedical Materials Research, 1986
- The effect of hydrocortisone acetate loaded poly(DL-lactide) films on the inflammatory responseJournal of Controlled Release, 1985
- In vivo biocompatibility studies. V. In vivo leukocyte interactions with biomerJournal of Biomedical Materials Research, 1984
- In vivo biocompatibility studies. II. Biomer: Preliminary cell adhesion and surface characterization studiesJournal of Biomedical Materials Research, 1984
- Biomaterial biocompatibility and the macrophageBiomaterials, 1984
- In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogelJournal of Biomedical Materials Research, 1983