Comparison of Lesion Sizes Produced by Cryoablation and Open Irrigation Radiofrequency Ablation Catheters
- 1 May 2008
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (5) , 528-534
- https://doi.org/10.1111/j.1540-8167.2007.01072.x
Abstract
Introduction: The relative lesion sizes created by large electrode cryoablation catheter and irrigated radiofrequency (RF) ablation are not known. The purpose of this study was to directly compare lesion sizes created by cryoablation and irrigated RF under controlled conditions. Methods and Results : Ablation lesions were created in freshly harvested porcine left ventricular myocardium in a blood‐filled tissue bath using an 8‐mm‐tip cryoablation catheter and a 3.5‐mm‐tip open‐irrigated RF ablation catheter. Lesions were created under all permutations of the following conditions: electrode orientation vertical (perpendicular) or horizontal (parallel) to the tissue, electrode contact pressure at 6 or 20 g, and blood flow at 0.2 or 0.4 m/s over the electrode‐tissue interface. The largest lesion volumes created with cryoablation were 961 ± 103 mm3, compared with the largest lesions volumes created with RF of 680 ± 48 mm3 (P < 0.001). The 3‐way interactions among electrode orientation, contact pressure, and superfusate blood velocity accounted for the variation in lesion volumes for both catheters (both r2= 0.97, both P < 0.0001). The greater contact pressure increased lesion size for both cryoablation and RF. For cryoablation, lesion sizes were increased by the horizontal orientation and by the lower blood flow velocity. For open‐irrigated RF, lesion sizes were significantly reduced by the horizontal orientation, however. Conclusions : Depending on conditions of electrode orientation, contact pressure, and blood velocity, either 8‐mm‐tip cryoablation or open‐irrigated RF may produce the larger lesion volumes. Open‐irrigated RF lesion sizes are reduced in the horizontal catheter orientation.Keywords
This publication has 19 references indexed in Scilit:
- Determinants of Lesion Sizes and Tissue Temperatures During Catheter CryoablationPacing and Clinical Electrophysiology, 2007
- Cryoablation compared with radiofrequency ablation for atrioventricular nodal re-entrant tachycardia: analysis of factors contributing to acute and follow-up outcomeEP Europace, 2006
- Incidence, Time Course, and Characteristics of Microbubble Formation During Radiofrequency Ablation of Pulmonary Veins with an 8‐mm Ablation CatheterPacing and Clinical Electrophysiology, 2006
- Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam PopCirculation, 2006
- Efficacy and Safety of Cryoenergy in the Ablation of Atrioventricular Reentrant Tachycardia Substrates in Children and AdolescentsJournal of Cardiovascular Electrophysiology, 2005
- Saline‐Irrigated Radiofrequency Ablation Electrode with External CoolingJournal of Cardiovascular Electrophysiology, 2005
- Catheter cryoablation of supraventricular tachycardia: results of the multicenter prospective “frosty” trialHeart Rhythm, 2004
- Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter AblationCirculation, 2003
- Transvenous Cold Mapping and Cryoablation of the AV Node in Dogs: Observations of Chronic Lesions and Comparison to Those Obtained Using Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 1998
- Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy DeliveryJournal of Cardiovascular Electrophysiology, 1991