Comparison of Imaging Protocols for 18F-FDG PET/CT in Overweight Patients: Optimizing Scan Duration Versus Administered Dose
Open Access
- 14 May 2009
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (6) , 844-848
- https://doi.org/10.2967/jnumed.108.060590
Abstract
The quality of 18F-FDG PET/CT images of overweight patients is often degraded. We evaluated the effect of optimizing injected dose or acquisition time on the quality of images of overweight patients using lutetium oxyorthosilicate PET/CT with high-performance detector electronics. Methods: We initially retrospectively measured radioactivity concentrations and signal-to-noise ratios (SNRs) in the liver relative to body weight for 80 patients who had undergone 18F-FDG PET/CT according to our standard protocol (injected dose, 3.7 MBq/kg; acquisition time, 2 min/bed position). The patients were grouped (n = 20 per group) according to baseline body weight as G1 (≤59 kg), G2 (60–69 kg), G3 (70–84 kg), and G4 (≥85 kg). We compared the SNRs of G1 with those of G2, G3, and G4 and calculated the ratio squared as a factor to correct the acquisition parameters for overweight patients. We then prospectively enrolled 120 patients according to the same body weight criteria. We multiplied the correction factors to optimize injected doses or acquisition times and defined dose-adjusted groups (n = 20 per group) and time-adjusted groups (n = 20 per group). G2 dose was defined as 5.59 ± 0.19 MBq/kg, G3 dose as 7.29 ± 0.33 MBq/kg, and G4 dose as 8.88 ± 0.43 MBq/kg. G2 time was defined as 3 min/bed position, G3 time as 4 min/bed position, and G4 time as 5 min/bed position. Results: Although liver activities did not significantly differ among G1 through G4 irrespective of patient weight, SNR progressively decreased as patient weight increased. The liver activities of G2 dose, G3 dose, and G4 dose were, respectively, 1.4-, 1.9-, and 2.5-fold higher than those of the baseline counterparts. Nevertheless, the increased liver activities of G2 dose, G3 dose, and G4 dose did not significantly affect SNR, compared with the baseline groups. In contrast, the SNR of G4 time was significantly higher than that of G4. Conclusion: Our findings suggest that the quality of images acquired from heavier patients can be maintained only by scanning for longer periods. Increasing the dose per kilogram of body weight did not improve the quality of lutetium oxyorthosilicate PET/CT images.Keywords
This publication has 7 references indexed in Scilit:
- Count-rate analysis from clinical scans in PET with LSO detectorsRadiation Protection Dosimetry, 2008
- PET/CT BiographTM Sensation 16Nuklearmedizin-Nuclear Medicine, 2006
- Ultra Low Dose CT Attenuation Correction Maps for Emission Computed TomographyPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2006
- Optimal dose of 18 F-FDG required for whole-body PET using an LSO PET cameraEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Impact of body habitus on quantitative and qualitative image quality in whole-body FDG-PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Is LSO the future of PET?European Journal of Nuclear Medicine and Molecular Imaging, 2002
- The AAPM/RSNA Physics Tutorial for ResidentsRadioGraphics, 1999