A pulsed Doppler echocardiographic method for calculation of pulmonary and systemic flow: accuracy in a canine model with ventricular septal defect.
- 1 September 1983
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 68 (3) , 597-602
- https://doi.org/10.1161/01.cir.68.3.597
Abstract
The accuracy of a quantitative, 2-dimensional, range-gated, Doppler echocardiographic method for estimating systemic and pulmonary flows was assessed by comparing them with simultaneous electromagnetic (EM) flow-meter determinations in an open-chest canine model with a ventricular septal defect, the size of which was varied. With each step-by-step variation in defect size, systemic and pulmonary flows were estimated by the Doppler method and matched to simultaneous pulmonary and aortic EM flow-meter recordings. The Doppler value for systemic blood flow was obtained by measuring the size of the aorta on a 2-dimensional echocardiographic image and sampling blood flow velocity in the ascending aorta. Because of high flow velocities and spectral broadening on the pulmonary artery Doppler flow curves in the presence of ventricular septal defects, pulmonary blood flow was measured as pulmonary venous return through the mitral valve orifice, with the size of the mitral orifice measured on the short axis by 2-dimensional echocardiography and with transflow curves obtained from apical views. For a total of 32 left-to-right shunt magnitudes obtained in 10 dogs, excellent correlations were found between ascending aortic Doppler and EM flow-meter values (r = 0.91, SEE [standard error of the estimate] = 0.11), between Doppler mitral valve flow and EM flow-meter main pulmonary artery flow values (r = 0.93, SEE = 0.52). This study demonstrates the accuracy of this 2-dimensional echocardiographic Doppler method for measuring pulmonary and systemic flows and their ratios in the presence of ventricular septal defects.This publication has 9 references indexed in Scilit:
- The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.Circulation, 1983
- Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast fourier transform spectral analysisThe American Journal of Cardiology, 1982
- The mitral valve orifice (MVO) method for noninvasive determination of cardiac output (CO) by two-dimensional (2D) echo/Doppler: Validation and initial clinical trialsThe American Journal of Cardiology, 1982
- Combined doppler and phased-array echocardiographic estimation of cardiac output.Circulation, 1981
- Transcutaneous Doppler method of measuring cardiac output—IIThe American Journal of Cardiology, 1980
- Transcutaneous method of measuring Doppler cardiac output—IThe American Journal of Cardiology, 1980
- Pulsed doppler echocardiographic measurement of beat-to-beat changes in stroke volume in dogs.Circulation, 1980
- Estimation of stroke volume changes by ultrasonic doppler.Circulation, 1977
- Transcutaneous measurement of blood flow velocity in the human aortaCardiovascular Research, 1976