Flow compensation in balanced SSFP sequences
Open Access
- 2 September 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (4) , 901-907
- https://doi.org/10.1002/mrm.20619
Abstract
In balanced steady‐state free precession (b‐SSFP) sequences, uncompensated first‐order moments of encoding gradients induce a nonconstant phase evolution for moving spins within the excitation train, resulting in signal loss and image artifacts. To restore these flow‐related phase perturbations, “pairing” of consecutive phase‐encoding (PE) steps is compared with a fully flow‐compensated sequence using compensating gradient waveforms along all three encoding directions. In volunteer studies, the quality of images acquired with the “pairing” technique was comparable to that of images obtained with the fully flow‐compensated technique, regardless of the selected view‐ordering scheme used for data acquisition. Nevertheless, the results of phantom experiments indicate that the pairing technique becomes ineffective at flow velocities exceeding roughly 0.5–1 m/s. Consequently, the additional scan time required to null the first gradient moments in a flow‐compensated b‐SSFP sequence makes the “pairing” technique preferable for applications in which slow to moderate flow velocities can be expected. Magn Reson Med, 2005.Keywords
This publication has 17 references indexed in Scilit:
- Analysis and compensation of eddy currents in balanced SSFPMagnetic Resonance in Medicine, 2005
- Accelerating cardiac cine 3D imaging using k‐t BLASTMagnetic Resonance in Medicine, 2004
- Steady-State Free Precession MR Imaging: Improved Myocardial Tag Persistence and Signal-to-Noise Ratio for Analysis of Myocardial MotionRadiology, 2004
- Flow artifacts in steady‐state free precession cine imagingMagnetic Resonance in Medicine, 2003
- Flow effects in balanced steady state free precession imagingMagnetic Resonance in Medicine, 2003
- Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricleJournal of Magnetic Resonance Imaging, 2001
- Real‐time cardiac cine imaging with SPIDER: Steady‐state projection imaging with dynamic echo‐train readoutMagnetic Resonance in Medicine, 2001
- Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agentsJournal of Magnetic Resonance Imaging, 2001
- 3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteriesMagnetic Resonance in Medicine, 2001
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001