Safety of Changing Intravenous Delivery Systems at Longer Than 24-Hour Intervals
- 1 August 1979
- journal article
- research article
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 91 (2) , 173-178
- https://doi.org/10.7326/0003-4819-91-2-173
Abstract
Routinely changing the intravenous delivery system (fluid containers and administration set) every 24 h is widely practiced in American hospitals to reduce the risk of septicemia caused by contaminated infusate. We did a prospective clinical study to ascertain whether changing at longer intervals could be justified. At the conclusion of infusion therapy through one system, both the cannula and an aliquot of remaining fluid were cultured quantitatively. Of 790 infusions, contaminated infusate was detected in one (0.39%) of 258 discontinued and sampled after 1 to 24 h of continuous use, three (0.84%) of 359 after 25 to 48 h, and one (0.58%) of 173 after 49 to 71 h; none of these five contaminated systems produced septicemia. However, five cannula-related septicemias were identified during the study, none associated with concordant contamination of infusate. Routinely replacing the delivery system every 48 h seems to be justified and could result in considerable savings to hospitals. Infection of the cannula wound and contamination of infusate seem to be unrelated.This publication has 10 references indexed in Scilit:
- Contamination of Intravenous Infusion Fluid: Effects of Changing Administration SetsAnnals of Internal Medicine, 1979
- Failure of Disposable Domes to Prevent Septicemia Acquired from Contaminated Pressure TransducersChest, 1978
- The Importance of Beta, the Type II Error and Sample Size in the Design and Interpretation of the Randomized Control TrialNew England Journal of Medicine, 1978
- Nosocomial outbreak of Candida parapsilosis fungemia related to intravenous infusionsArchives of internal medicine (1960), 1977
- A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related InfectionNew England Journal of Medicine, 1977
- Pseudomonas Species Bacteremia Caused by Contaminated Normal Human Serum AlbuminThe Journal of Infectious Diseases, 1977
- Pressure monitoring devices. Overlooked source of nosocomial infectionJAMA, 1976
- Nationwide epidemic of septicemia caused by contaminated intravenous productsThe American Journal of Medicine, 1976
- Infection Control in Intravenous TherapyAnnals of Internal Medicine, 1973
- Sepsis Caused by Contaminated Intravenous FluidsAnnals of Internal Medicine, 1972