Short term variability of single breath carbon monoxide transfer factor
Open Access
- 1 May 2001
- Vol. 56 (5) , 358-361
- https://doi.org/10.1136/thorax.56.5.358
Abstract
BACKGROUND When monitoring patients with chronic lung disease it is important to distinguish genuine changes in gas transfer over time from natural variability. This study aims to define the coefficient of repeatability for routine measurements of single breath transfer factor (Tco) and transfer coefficient (Kco). METHODS Sixty eight subjects (32 with emphysema, 36 healthy volunteers) had Tcomeasured twice at a mean (SD) interval of 7.5 (1.3) days. On each occasion a standard protocol (conforming to BTS guidelines) was followed, comprising duplicate measurements satisfying standard technical criteria. The mean of these duplicates was recorded. For the pooled data changes in Tco and Kco between study days were expressed as coefficient of repeatability. RESULTS The coefficient of repeatability was ±1.60 mmol/min/kPa for Tco and ±0.24 mmol/min/kPa/l for Kco. Correcting Tco and Kco for prevailing barometric pressure or carboxyhaemoglobin level made no significant difference to the results. CONCLUSIONS The quoted limits for variability in gas transfer over time are valid for a wide range of clinically relevant values. Changes in Tco and Kco greater than these limits are unlikely to arise from natural variation.Keywords
This publication has 13 references indexed in Scilit:
- Standardization of single-breath transfer factor (TLCO); derivation of breathholding timeEuropean Respiratory Journal, 1992
- Intraindividual Variability in Serial Measurements of DlCOand Alveolar Volume over One Year in Eight Healthy Subjects Using Three Independent Measuring SystemsAmerican Review of Respiratory Disease, 1989
- Effect of ethanol on transfer factor: the importance of posture.Thorax, 1987
- Short term variability in FEV1 and bronchodilator responsiveness in patients with obstructive ventilatory defects.Thorax, 1987
- Carbon monoxide in breath in relation to smoking and carboxyhaemoglobin levels.Thorax, 1981
- STANDARDIZED SINGLE BREATH NORMAL VALUES FOR CARBON-MONOXIDE DIFFUSING-CAPACITYPublished by Elsevier ,1981
- REFERENCE SPIROMETRIC VALUES USING TECHNIQUES AND EQUIPMENT THAT MEET ATS RECOMMENDATIONSPublished by Elsevier ,1981
- Lung function in healthy British women.Thorax, 1979
- Assessment of respiratory function in patients with chronic obstructive airways disease.Thorax, 1979
- Effect of Variability in Gas Analysis on the Reproducibility of the Pulmonary Diffusing Capacity by the Single Breath MethodThorax, 1963