Limits to the accuracy of vessel diameter measurement in MR angiography
- 1 November 1998
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 8 (6) , 1228-1235
- https://doi.org/10.1002/jmri.1880080608
Abstract
This work addresses the fundamental limits imposed by the MRI process on the accuracy with which vessel diameters and cross‐sectional areas can be derived from time‐of‐flight (TOF) and phase‐contrast (PC) MR source images. By means of simulations and in vitro experiments, it is demonstrated that, even in the absence of flow‐related artifacts, severe inaccuracies in the determination of diameters or cross‐sectional areas may occur solely because of the physical process of the MR image acquisition. Resolution and intraluminal saturation have strong effects on the vessel appearance and thus on the diameter estimation error. It is shown that low resolution leads to diameter overestimation or even underestimation and that intraluminal saturation causes severe underestimation, even for relatively low flip angles. Velocity and velocity encoding do not have a major influence on lumen appearance in PC images. Accurate diameter estimations can be attained only if lumen diameters constitute at least three pixels for both TOF and PC acquisitions, provided that intraluminal saturation is suppressed or avoided. Additionally, since the constitution of TOF and PC images is dissimilar, lumina should be analyzed differently to obtain accurate diameters and cross‐sectional areas.Keywords
This publication has 22 references indexed in Scilit:
- Quantification of Atheromatous Stenosis in the Extracranial Internal Carotid ArteryCerebrovascular Diseases, 1995
- Motion Induced Phase Shifts in MR: Acceleration Effects in Quantitative Flow Measurements—A ReconsiderationMagnetic Resonance in Medicine, 1995
- Cardiac‐gated MR angiography of pulsatile flow: K‐space strategiesJournal of Magnetic Resonance Imaging, 1995
- Turbulent Fluctuation Velocity: The Most Significant Determinant of Signal Loss in Stenotic VesselsMagnetic Resonance in Medicine, 1995
- Pulsation artifact in short TR MR imaging and angiography: Exacerbation with signal averagingJournal of Magnetic Resonance Imaging, 1994
- Mechanisms of signal loss in magnetic resonance imaging of stenosesMedical Physics, 1993
- Effects of acceleration on the accuracy of MR phase velocity measurementsJournal of Magnetic Resonance Imaging, 1992
- Mechanisms of flow‐induced signal loss in MR angiographyJournal of Magnetic Resonance Imaging, 1992
- On the nature and reduction of the displacement artifact in flow imagesMagnetic Resonance in Medicine, 1991
- Artifacts in maximum-intensity-projection display of MR angiograms.American Journal of Roentgenology, 1990