The Challenges of Quantitative Measurement of Lung Deposition Using 99mTc-DTPA from Delivery Systems with Very Different Delivery Times
- 1 September 2007
- journal article
- research article
- Published by Mary Ann Liebert Inc in Journal of Aerosol Medicine
- Vol. 20 (3) , 320-330
- https://doi.org/10.1089/jam.2007.0620
Abstract
In quantifying aerosol delivery, the drug is often mixed with a radiolabel such as 99mTc-DTPA whose deposition is used as a proxy for the drug. 99mTc-DTPA deposited in the lung is cleared by a combination of absorption into the pulmonary circulation and mucociliary clearance. If administration is not instantaneous, the image will not include that clearance during administration, a problem raised if comparing devices with different administration times. However, if rates of clearance are measured, it will be possible to “correct” the initial image for the clearance that occurred during administration and before counting. Five adult males inhaled a 5-mL solution containing 99mTc-DTPA from a breath enhanced jet nebulizer (LC Plus®) over the course of 10 min and a 1.25-mL solution from a vibrating membrane device (eFlow®), which was delivered in 2.5 min. Quality assurance was the radioactivity count balance (RCB) defined as the difference in the total radioactivity pre-nebulization less post, divided by pre, and expressed as a percentage. Attenuation calculations used a 57Co flood source (Macey and Marshall). The “correction” for the clearance of 99mTc-DTPA was 0.91 ± 0.04 (mean ± SD) for the LC Plus® and 0.96 ± 0.02 for the eFlow®. RCB was −0.6 ± 3.5% for the LC Plus® and −4.7 ± 6.4% for the eFlow®, implying acceptable accuracy. For the LC Plus®, lung deposition was 15.9(13.4, 18.4)% (mean and 95% CI) of the charge dose, and for the eFlow® it was 32.0(29.0, 35.0)%. This technique gave an acceptable level of accuracy for quantitative planar imaging and allowed the comparison of delivery from devices with very different rates of delivery.Keywords
This publication has 24 references indexed in Scilit:
- Inhaled insulinBMJ, 2006
- A Randomized Trial of Inhaled Cyclosporine in Lung-Transplant RecipientsNew England Journal of Medicine, 2006
- Airway Retention of Materials of Different Solubility following Local Intrabronchial Deposition in DogsJournal of Aerosol Medicine, 2003
- Significant Microbiological Effect of Inhaled Tobramycin in Young Children with Cystic FibrosisAmerican Journal of Respiratory and Critical Care Medicine, 2003
- A randomised clinical trial of nebulised tobramycin or colistin in cystic fibrosisEuropean Respiratory Journal, 2002
- Mucociliary clearance in patients with cystic fibrosis and in normal subjects.American Journal of Respiratory and Critical Care Medicine, 1994
- Investigation of factors affecting ashesion of 99Tcm labelled colloids to glass vialsNuclear Medicine Communications, 1990
- Simultaneous measurement of lung clearance rates for Tc- and In-DTPA in normal and damaged lungsJournal of Applied Physiology, 1989
- Long‐term effects of inhaled tobramycin in patients with cystic fibrosis colonized with Pseudomonas aeruginosaPediatric Pulmonology, 1989
- Measurement of pulmonary epithelial permeability with 99mTc-DTPA aerosolSeminars in Nuclear Medicine, 1986