Exploring the Importance of the Relative Solubility of Matrix and Analyte in MALDI Sample Preparation Using HPLC
- 29 July 2004
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (17) , 5157-5164
- https://doi.org/10.1021/ac049566m
Abstract
New insight into the role of solubility in the sample preparation process for MALDI MS is reported. Reversed-phase gradient HPLC conditions were developed that enable the analysis of a broad range of analyte polarities with a single method. This HPLC method was used to establish a relative polarity scale for a series of 15 MALDI matrix materials, a set of example peptides, and a series of model polymer materials with a broad range of polarity. Examples of each polymer type within the range of 6000-10,000 were analyzed with six matrixes that cover a broad range of polarity using MALDI TOFMS. With regard to polymer signal-to-noise ratio, the matrix and polymer combinations that had a close match of HPLC retention time produced the best MALDI spectra. Conversely, the matrix and polymer combinations that have a large difference in HPLC retention time produced poor MALDI spectra. The results suggest that there is a relationship between polarity (solubility) and effective MALDI sample preparation. The relative HPLC retention time of an unknown polymer can serve as a starting point for predicting the matrix (or range of matrixes) that would be most effective.Keywords
This publication has 19 references indexed in Scilit:
- Determination of octanol-water partition coefficients of polar polycyclic aromatic compounds (N-PAC) by high performance liquid chromatographyChemosphere, 1997
- Influence of Matrix Solution Conditions on the MALDI-MS Analysis of Peptides and ProteinsAnalytical Chemistry, 1996
- Mass Discrimination Effects in an Ion Detector and Other Causes for Shifts in Polymer Mass Distributions Measured by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass SpectrometryMacromolecules, 1996
- A facile sample preparation for the analysis of synthetic organic polymers by matrix‐assisted laser desorption/ionizationJournal of Mass Spectrometry, 1993
- 2,5-Dihydroxybenzoic acid: a new matrix for laser desorption—ionization mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1991
- A practical guide to polymer miscibilityPolymer, 1990
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1988
- Laser desorption time-of-flight mass spectrometry of low-molecular-weight polymersMacromolecules, 1986
- Direct measurement of octanol-water partition coefficients by high-pressure liquid chromatographyJournal of Medicinal Chemistry, 1976